AR83.30-D-5540B | Remove, install evaporator | 16.3.01 |
MODELS 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HH9) Automatic air conditioning "Tempmatic"
| Removing, installing | ||
| The evaporator is a component of the heater housing and can only be removed and installed or replaced together with this | ||
Danger! | Risk of explosion from welding or braizing work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant | Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or naked flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Do not carry out any repair work on the air conditioning system circuit unless the system is drained. | |
1 | Drain air conditioning | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with AC | |
2 | Remove heater unit | ||
3 | Install in the reverse order | ||
4 | Evacuate air conditioning system, refill and check for function and leaks |