AR83.30-D-5540B | Remove, install evaporator | 16.3.01 |
MODELS 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HH9) Automatic air conditioning "Tempmatic"
| Removing, installing | ||
| The evaporator is a component of the heater housing and can only be removed and installed or replaced together with this | ||
Danger! | Risk of explosion from welding or braizing work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant | Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or naked flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Do not carry out any repair work on the air conditioning system circuit unless the system is drained. | |
1 | Drain air conditioning | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with AC | |
2 | Remove heater unit | ||
3 | Install in the reverse order | ||
4 | Evacuate air conditioning system, refill and check for function and leaks |
Referenced documents
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ar8325d1000b Remove/install heater housing
- ar8330d1760a Drain, evacuate and refill air conditioning, check function and check for leaks
- as8300z000101a Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.