1 | Electrical connector |
2 | Hose clamps |
3 | Bolts |
4 | Purge valve |
S47.30-4514-04
Danger | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Release electrical connector(1) and disconnect. | ||
2 | Remove clamps (2) and remove hoses from the purge valve (4). | Seal connections. | |
Record plug | |||
Hose clamp pliers | |||
3 | Remove screw/bolts (3). | M6 | |
4 | Remove purge valve (4). | ||
5 | Install in the reverse order. | ||
| Check | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
6 | Check for leaktightness when engine is running. | Visual inspection only. |
454 589 00 37 00
Hose clamp pliers
129 589 00 91 00
Record plug
참조 문서
- ah0000p500001a 불순물 및 이물질에 의한 손상 방지 지침
- ah5400p000101a 정전기 방전으로 인한 전자 부품 손상 방지 지침
- as0000z000501a 엔진이 작동 중인 상태에서 급발진에 의한 사고 위험 시동 또는 구동 중인 엔진 근처에서 작업할 때 차량에 부딪히거나 열에 의한 상해 위험
- as4700z000101a 인화에 의한 폭발 위험, 연료의 흡입 및 음용에 의한 중독 위험, 연료의 피부 및 안구 접촉에 의한 상해 위험