Modification notes
652 589 00 33 21
Hollow cylinder
Hand pump
Extraction and insertion tool
Hydraulic hose (complete)
164 589 01 43 00
652 589 00 33 22
652 589 00 33 23
001 589 01 63 00
Retaining belt
Threaded spindle
652 589 00 33 11
Repair materials
Number | Designation | Order number |
BR00.45-Z-1010-06A | Lubricant, rubber assembly 1 l | A 000 989 03 67 |
P35.10-2310-09
Shown: Removal of left front rubber mount
10 Front rubber mount
11 Rear axle carrier
12 Threaded spindle
13 Hollow cylinder
14 Hydraulic hose
H Upright
K Support plates
L Press-out sleeve
Arrow: View towards rear axle carrier
15 Hand pump
16 Nuts
17 Bolts
G Plate
Removing
1 Assemble plate (G), upright (H) and support plates (K) with nut (16) and fasten with bolts (17) to the hollow cylinder (13).
2 Position support plates (K) on front rubber mount (10) and tighten nuts (16).
3 Feed the threaded spindle (12) through the hollow cylinder (13), the plate (G) and the front rubber mount (10) and screw on the press-out sleeve (L).
The notches on the press-out sleeve (L) must sit on the elevations on the front rubber mount (10).
4 Press out the front rubber mount (10).
The extraction tool must be held when pressing out otherwise it can fall.
The pressure in the hand pump (15) must not exceed
140 bar.
P35.10-2311-09
Shown: Installation of left front rubber mount
10 Front rubber mount
11 Rear axle carrier
12 Threaded spindle
F Nut block
M Front plate
Arrow: View towards rear axle carrier
13 Hollow cylinder
14 Hydraulic hose
15 Hand pump
Install
5 Assemble hollow cylinder (13), hydraulic hose (14) and hand pump (15).
6 Fit front plate (M) and front rubber mount (10) on to the hollow cylinder (13).
7 Feed threaded spindle (12) through the hollow cylinder (13), front plate (M), front rubber mount (10) and the rear axle carrier (11), and screw on nut block (F).
Be careful when screwing on the nut block (F). Otherwise the paintwork on the rear axle carrier (11) can be damaged.
8 Align front rubber mount (10) with markings and press in.
Use lubricant The pressure in the hand pump (15) must not exceed 140 bar.