716 589 01 15 00
Drift
000 589 89 33 00
Puller
126 589 02 09 00
Socket wrench bit
901 589 00 07 00
Pin wrench
Remove
1 | Unscrew collar nut (1) using socket. |
While doing so, counterhold output flange (2) using key wrench. |
2 | Pull output flange (2) off the output shaft. |
For seized output flange (2), | |
| |
Use puller. |
3 | Check output flange (2) for damage, replace as per findings. |
D27.50-1101-01
D27.50-1102-01
Install
4 | Push output flange (2) onto output shaft. |
5 | Screw on collar nut (1) using socket . |
Install new collar nut (1). |
6 | Secure collar nut (1) using drift . |
Secure collar nut (1) crosswise at cutouts on output shaft. |
D27.50-1101-01
D27.50-1103-01