AR83.70-D-5807G | Remove and install combustion and heater air blower | 5.12.06 |
MODEL 906 with CODE (H11) Warm air auxiliary heater
D83.70-1292-06
1 Cover
2 Auxiliary heating control unit
3 Heat exchanger with combustor
4 Casing housing
5 Flange gasket
6 Seal
7 Combustion and heater air blower
8 Locking brackets
A - D Tightening sequence
| Remove/install | ||
1 | Remove heater unit | Model 906.6 and 906.7 AIRTRONIC D4S heater unit | |
Model 906.1 and 906.2 AIRTRONIC D2 heater unit | |||
2 | Remove heater unit from housing | Model 906.6 and 906.7 AIRTRONIC D4S heater unit | |
3 | Release locking brackets (8) of cover (1) | ||
4 | Lift up cover (1) and remove from jacket housing (4) of heater unit | ||
5 | Remove auxiliary heater control unit (2) | ||
6 | Remove heater unit from jacket housing | ||
7 | Remove combustion air and hot air blower (7) from heat exchanger with combustor (3) | Installation: Observe the tightening sequence (A - D) for bolts. | |
8 | Remove gasket (6) | Installation: Clean sealing surfaces. Replace gasket (6). | |
9 | Install in the reverse order |