1 | Desiccant cartridge |
2 | Refrigerant condenser |
3 | Screw |
4 | Sealing rings |
S83.30-A005-82
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Remove refrigerant condenser (2). | ||
2 | Remove bolt (3) . | Screw, desiccant cartridge to refrigerant condenser for high-voltage battery cooling system | |
3 | Remove receiver drier (1) from refrigerant condenser (2). | ||
| Compressor oils (specification 362.1) | ||
Seal openings on receiver drier (1) and on refrigerant condenser (2). | |||
Installation: If the packaging is damaged or the stop plugs are missing on a new receiver drier (1), this new receiver drier (1) must not be installed. | |||
Assembly tool | |||
Record plug | |||
4 | Install in the reverse order. |
000 589 93 63 00
Assembly tool
129 589 00 91 00
Record plug
参照文書
- ah8330n000301a 冷媒 (R134a) の取扱いについての注意事項
- ah8330n000501a リペア作業時のエアコンの冷媒回路および構成部品の水分付着からの保護
- ar8330d0013te
- as8300z000601a R134aが充填されたエアコンの過熱された冷媒蒸気を 吸い込むことによる中毒の危険 液化した冷媒R134aの飛散による皮膚や目への接触 および圧力のかかった部品 を使用する作業で�
- bb0040p036201a コンプレッサオイル(明細仕様 362.1)