D83.30-A031-79
Shown with heat exchanger removed |
1 | Refrigerant condenser | 4 | Coolant hose | 7 | Refrigerant line | ||
2 | Desiccant cartridge | 6 | Refrigerant line | 9 | Coolant hose | ||
3 | Pressure and temperature sensor |
D83.30-A032-79
Shown with heat exchanger removed |
1 | Refrigerant condenser | 3 | Pressure and temperature sensor | 11 | Electrical connector | ||
2 | Desiccant cartridge | 10 | Nuts |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Remove/install | ||
1 | Remove heat exchanger. | ||
2 | Remove coolant hoses (4, 9) from refrigerant condenser (1). | ||
Collect escaping coolant in a suitable container. Seal connections. | |||
Set of protective covers | |||
3 | Remove refrigerant line (7) from refrigerant condenser (1). | ||
Seal refrigerant line (7). | |||
Record plug | |||
4 | Remove refrigerant line (6) from refrigerant condenser (1). | ||
Seal refrigerant line (6). | |||
Record plug | |||
5 | Disconnect electrical connector (11) at pressure and temperature sensor (3). | ||
6 | Remove nuts (10) from refrigerant condenser (1). | ||
Topical note | Notes on self-locking nuts and bolts | ||
Nut, refrigerant condenser for high-voltage battery cooling system to supporting frame | |||
7 | Remove refrigerant condenser (1) with attached receiver drier (2) and installed pressure and temperature sensor (3). | ||
8 | Install in the reverse order. |
001 589 01 91 00
Set of protective covers
129 589 00 91 00
Record plug
参照文書
- ah0000n000101a セルフロッキング·ナットおよびボルトに関する注意事項
- ah0000z030001a 高電圧車両電源回路および/またはリチウムイオンバッテリおよび/またはガスドライブシステムならびに個人用保護装備の装備車に関する一般注意事項
- ah8330n000401a 損傷または漏れがあるエアコンの取扱い
- ah8330n000501a リペア作業時のエアコンの冷媒回路および構成部品の水分付着からの保護
- ar0850d0302te
- ar0850p001801eq クーラントホースコネクタの開閉
- ar8330d7840te
- ar8330d7841te
- as0000z003501a 30 V交流電圧 (AC) または60 V直流電圧 (DC) がかかった構成部品およびシステムでの作業時の生命の危険
- as2000z000101a 高温のクーラントが高圧で噴出して、皮フおよび目に火傷を負う危険があります。クーラントを誤飲すると、中毒になる危険があります。