1 | Shutoff valve |
2 | Electrical connector |
3 | Nut |
4 | Sealing ring |
D83.30-A019-76
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Check | ||
1 | Read out Vehicle Documentation (VeDoc) and check code entries. | The shutoff valve (1) can be installed in the "NO" version or in the "NC" version. | |
If code OB0 (NO SHUTOFF VALVE) is present in VeDoc, | |||
| |||
remove code OB0 (NO SHUTOFF VALVE). | |||
Codes can only be removed in VeDoc by a user with write permission. | |||
| Remove/install | ||
2 | Remove refrigerant line from vehicle interior expansion valve. | ||
3 | Disconnect electrical connection (2). | ||
4 | Remove nut (3). | Nut, refrigerant line to shutoff valve for refrigerant circuit in vehicle interior | |
5 | Remove shutoff valve (1). | ||
| Compressor oils (specification 362.1) | ||
Plug openings. | |||
Installation: Replace sealing ring (4) and coat with compressor oil. | |||
Record plug | |||
6 | Replace shutoff valve (1). | If code OB0 (NO SHUTOFF VALVE) was present in VeDoc. | |
The shutoff valve (1) in version "NO" must be replaced by a shutoff valve (1) in version "NC". | |||
7 | Install in the reverse order. |
129 589 00 91 00
Record plug
参照文書
- ah0000z030001a 高電圧車両電源回路および/またはリチウムイオンバッテリおよび/またはガスドライブシステムならびに個人用保護装備の装備車に関する一般注意事項
- ah5400p000101a 静電気放電による電子構成部品の損傷を防ぐための注意事項
- ah8330n000301a 冷媒 (R134a) の取扱いについての注意事項
- ah8330n000501a リペア作業時のエアコンの冷媒回路および構成部品の水分付着からの保護
- ar8330d7835te
- as0000z003501a 30 V交流電圧 (AC) または60 V直流電圧 (DC) がかかった構成部品およびシステムでの作業時の生命の危険
- as8300z000601a R134aが充填されたエアコンの過熱された冷媒蒸気を 吸い込むことによる中毒の危険 液化した冷媒R134aの飛散による皮膚や目への接触 および圧力のかかった部品 を使用する作業で�
- bb0040p036201a コンプレッサオイル(明細仕様 362.1)