Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.Model 910 with engine 780.703 | |
Danger | Risk of explosion when using a forming gas with incorrect mixing ratio. Risk of suffocation due to inhalation of forming gas. Risk of injury due to bursting of high-pressure hoses. | Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
| Check | ||
1 | Discharge and evacuate air conditioning system. | ||
2 | Fill air conditioning with forming gas and check pressure drop. | ||
| 000 588 19 21 00 Leak tester | ||
| |||
Do not fill air conditioning system with forming gas unless engine is cold. | |||
When connecting and when operating the leak tester, the complete work procedure must be conducted in accordance with the manufacturer's operator's manual. | |||
Model 910 with engine 780.703Pressure drop in refrigerant circuit filled with test gas | |||
Model 907 | |||
If a pressure drop was detected, | |||
| |||
locate leakage in air conditioning system using gas detection unit. | |||
| 000 588 03 21 00 Gas detector | ||
Observe operator's manual for gas detection unit. | |||
If a leak is present, | |||
| |||
replace affected air conditioning system component parts. | |||
3 | Vent used forming gas from refrigerant circuit using leak tester. | Observe operator's manual for the leak tester. | |
4 | Fill air conditioning. |
参照文書
- ah0000z030001a 高電圧車両電源回路および/またはリチウムイオンバッテリおよび/またはガスドライブシステムならびに個人用保護装備の装備車に関する一般注意事項
- ah8330n000401a 損傷または漏れがあるエアコンの取扱い
- ah8330n000501a リペア作業時のエアコンの冷媒回路および構成部品の水分付着からの保護
- ar8330d1760ts
- as0000z003501a 30 V交流電圧 (AC) または60 V直流電圧 (DC) がかかった構成部品およびシステムでの作業時の生命の危険
- as8300z000102a 間違った混合割合のフォーミングガスの使用による 爆発の危険 フォーミングガスの吸い込みによる窒息の危険。高圧ホースの破裂による負傷の危険。
- ws4700p0019b 000 588 03 21 00 ガス・リーク・テスタ
- ws8300p0035b 000 588 19 21 00 リークテスター