D15.40-1113-08
1 Bolts
2 Electrical line
G2/7 Generator
3 Cap
4 Electrical connector
| Remove/install | ||
1 | Lift/jack up vehicle | ||
2 | Disconnect battery ground line | ||
Danger! | Risk of injury caused by moving parts that can pinch, crush or, in extreme cases, even sever extremities | No parts of the body or limbs should be within the operating range of the mechanism when moving components. | |
3 | Release tension on poly-V belt and remove belt pulley from alternator (G2/7) | ||
4 | Remove cap (3) and disconnect electrical line (2) on alternator (G2/7) | | |
5 | Unplug electrical connector (4) at alternator (G2/7) | ||
6 | Remove bolts (1) and remove alternator (G2/7) | | |
7 | Install in the reverse order |
Alternator
参照文書
- ar0060d1000h 車両リフト·アップ、ジャッキ·アップ
- ar1322d390205us
- ar5410d0003sd
- as0000z000901a 手指をはさまれたり、締め付けられて負傷する危険があります。注意をおこたると、メカニズムに巻き込まれて、手指が切断される危険もあります。