1 | Drain screw |
2 | Filling screw |
G08.00-A002-76
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Caution | Risk of injury to skin and eyes due to handling of transmission oil. Health risk caused by swallowing transmission oil | Wear protective gloves, protective clothing and safety glasses. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Draining | |||
1 | Remove lower engine compartment paneling. | ||
| |||
2 | Clean area surrounding drain screw (1) and filling screw (2). | ||
3 | Remove filling screw (2). | ||
4 | Remove drain screw (1) and completely drain off transmission oil. | To do so, place a suitable receptacle under drain screw (1). | |
5 | Screw in new drain screw (1) with new sealing ring. | | |
Drain screw to housing of axle drive module | |||
Pour in | |||
6 | Pour in transmission oil until it reaches the lower edge of the filler opening. | Transmission oil filling capacity | |
7 | Screw in new filling screw (2) with new sealing ring. | | |
Filling screw to housing of axle drive module | |||
8 | Install lower engine compartment paneling. | ||
| |||
9 | Confirm conducted operations in maintenance booklet or in Digital Service Booklet (DSB). |
参照文書
- ah0000p500001a 汚れおよび異物による損傷防止に関する注意事項
- ah0000z030001a 高電圧車両電源回路および/またはリチウムイオンバッテリおよび/またはガスドライブシステムならびに個人用保護装備の装備車に関する一般注意事項
- ar6120d1105ts
- as0000z000201a 高温になっているか、あるいは赤熱している部品を取り扱う場合に、火傷を負うあるいは失明する危険があります。
- as0000z003501a 30 V交流電圧 (AC) または60 V直流電圧 (DC) がかかった構成部品およびシステムでの作業時の生命の危険
- as0040z000101a トランスミッションオイルを取り扱う際に皮膚や目を 負傷する危険。トランスミッションオイルの誤飲による健康被害