07.1-229 Adjusting microswitch at injection pump (model 202)
Preceding work: Removing and installing intake manifold (14-180). | Job no. of Job Texts and Work Units or Standard Texts and Flat Rates: |
Locking screw (8d) of adjusting cam | slacken. |
Gauge (8c) | fit on to full load stop. |
Control lever (16) of injection pump | turn until it makes contact with the gauge (8c). |
Adjusting without multimeter | |
Adjusting cam (8e) | turn anti-clockwise until both microswitches operate audibly (clicking noise). Note Microswitch (S27/6) is switched to 10° and 15°. |
Adjusting with multimeter | |
Adjusting cam (8e) | turn anti-clockwise until the readout in the multimeter is W (see connection diagram). Note Microswitch (S27/6) is operated at 15° and 10° before full load. |
Locking screw (8d) of adjusting cam | tighten and remove gauge. |
Switching points | check. |
Shop-made tool
Gauge
Wire 250 mm long, 3 mm dia.
Washer OD 30 mm, ID 10 mm.
Wire must be welded to washer.
P07-6080-13
Connection diagram of microswitch
Unplug connector at microswitch (S27/6) and connect multimeter to connectors 1 and 3.
P07-6512-13