gf1530g3000a

Starter control - function

Tipo gf · tema 15.30 · versione 0100 · 2020-01-02

Valido per: Engine 900.91/92 in model 000.001 Engine 902.91/93 in model 000.001 Engine 904.94/95/96/97 in model 000.001 Engine 906.93/94/95/96/98/99 in model 000.001 Engine 924.91/93/94 in model 000.001 Engine 925.9 in model 000.001 Engine 926.91/92/93/95/97/98 in model 000.001

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 1 Motore › 15 Impianto elettrico motore › 15.30 Motorino d'avviamento — Serie 000 (modelli 001) · Serie 900 (modelli 91*, 92*) · Serie 902 (modelli 91*, 93*) · Serie 904 (modelli 94*, 95*, 96*, 97*) · Serie 906 (modelli 93*, 94*, 95*, 96*, 98*, 99*)

Valido anche per motori/cambi: 924 91*, 924 93*, 924 94*, 925 9**, 926 91*, 926 92*, 926 93*, 926 95*, 926 97*, 926 98*

GF15.30-G-3000A

Starter control - function

17.12.2019

Engine

900.91/92 in model 000.001

Engine

902.91/93 in model 000.001

Engine

904.94/95/96/97 in model 000.001

Engine

906.93/94/95/96/98/99 in model 000.001

Engine

924.91/93/94 in model 000.001

Engine

925.9 in model 000.001

Engine

926.91/92/93/95/97/98 in model 000.001

The starter control function is described using engine 926.9 (6 cylinders) as an example.

Starter control - function

G07.15-A037-79

0

Ignition OFF

S10

Engine start button

1

Circuit 15R ON

S11

Engine stop button

2

Circuit 15 On

Y600

Cylinder 1 single injection pump

3

Circuit 50

Y601

Cylinder 2 single injection pump

A3

Drive control (CPC) control unit

Y602

Cylinder 3 single injection pump

A6

Engine management (MR) control unit

Y603

Cylinder 4 single injection pump

B15

Crankshaft position sensor

Y604

Cylinder 5 single injection pump

B16

Camshaft position sensor

Y605

Cylinder 6 single injection pump

CAN 4

Drive train CAN

A

Input signals

M1

Starter

B

Output signals

S1a

Ignition lock

General

Actuation of the starter takes place exclusively over the circuit 50 output on the engine management (MR) control unit.

This makes it possible to protect the starter from mechanical and thermal overload (start time limitation, overspeed limiting device).

Since the starter end stage in the engine management (MR) control unit does not deliver sufficient power or is not designed for high currents, there is a front-end relay between the engine management (MR) control unit and the engaging relay of the starter.

Actuation of the starter takes place:

If the circuit 50 (3) signal from the ignition lock is detected at the input of the engine management (MR) control unit

If the engine start button is pressed

If the engine start and engine stop buttons are pressed at the same time

Preconditions

Power supply (circuit 30 and circuit 15 On (2)) available at engine management (MR) control unit.

Electronic immobilizer from DAS deactivated

Starter lockout canceled, i.e.:

Transmission in neutral position (only for start request via the engine start button)

Power take-off, where present, switched off

Engine off or engine speed below 50 rpm

Function

If all preconditions are met and the ignition lock or the engine start button is actuated or a corresponding message with the start request is received via the drive train CAN, the engine management (MR) control unit actuates the engaging relay of the starter via the front-end relay.

The starter sets the engine in motion. With the aid of the rpm signals from the crankshaft position sensor and the camshaft position sensor, the engine management (MR) control unit checks whether the starter is turning the engine at a minimum speed of 50 rpm.

Actuation of the starter following a start request via the ignition lock

The drive control (CPC) control unit and the engine management (MR) control unit receive the signal for the start request directly once circuit 15 On (2) has been switched on and circuit 50 (3) has been activated at the ignition lock.

The drive control (CPC) control unit then sends a start request message via the drive train CAN to the engine management (MR) control unit which it compares with the circuit 50 (3) signal coming directly from the ignition lock (consistency check).

If the circuit 50 (3) signal is present at the engine management (MR) control unit without the message being sent by the drive control (CPC) control unit, then the error "Circuit 50 inconsistent" will be stored in the fault memory after 1 s and the start will be delayed by this period of time. This redundancy means that it is still possible to start the engine via circuit 50 (3) if the CAN bus system fails, for example.

If the engine management (MR) control unit receives the circuit 50 (3) signal simultaneously over the circuit 50 connection on the control unit input and via the drive train CAN, the engine management (MR) control unit will actuate the starter immediately (without delay).

The starter continues to be actuated until the start request is retracted, the engine has reached the starter break-off speed (engine speed of approx. 450 rpm for a warm engine and up to approx. 650 rpm for a cold engine) or the maximum start time of 90 s has been exceeded (start time limitation).

Actuation of the starter following a start request via the engine start button

The engine management (MR) control unit reads in the signals of the engine start button directly. If the engine start button is pressed, the engine management (MR) control unit sends a start request message to the drive control (CPC) control unit via the drive train CAN.

The drive control (CPC) control unit checks whether this is permissible, i.e. the preconditions that must be fulfilled to lift the starter lockout, and sends the start enable to the engine management (MR) control unit via the drive train CAN.

The engine management (MR) control unit then actuates the starter until the engine start button is released, the starter break-off speed is reached or the actuation is interrupted autonomously to protect against mechanical or thermal overload (start time limitation).

Actuation of the starter when the engine start and engine stop buttons are pressed simultaneously

If the engine start and engine stop buttons are pressed at the same time, the engine can be turned over for servicing without the engine starting as, in this case, actuation of the single injection pumps for cylinders 1 to 6 is interrupted by the engine management (MR) control unit.

If the starter was actuated by pressing the engine start button or by pressing the engine start and engine stop buttons at the same time, for safety reasons it is possible to start the engine via the ignition lock only once the ignition has been switched off and back on again.

The signal which initiated a start must always be retracted again for safety reasons before a new start is possible based on the same signal (start locking).

Engine management (MR) control unit, component description

A6

GF07.15-G-5003A

Component description for the crankshaft position sensor

B15

GF07.04-G-6011A

Component description for camshaft position sensor

B16

GF07.04-G-6021A

Engine start button, component description

S10

GF07.15-G-4126A

Engine stop button, component description

S11

GF07.15-G-4127A

Single injection pump, component description

Y600, Y601, Y602, Y603, Y604, Y605

GF07.02-G-2111A