Check pneumatic working pressure at exhaust aftertreatment system metering device

Tipo ar · tema 14.40 · versione 0200 · 2016-02-12

Valido per: Cumbustion engine 457.9 with Vehicle 382.15# #D, 634.0## #D with CODE MS5 (BlueTec 5)

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 1 Motore › 14 Collettore di scarico, freno motore, impianto di depurazione gas di scarico › 14.40 Post-trattamento gas di scarico, AdBlue — Serie 382 (modelli 15*) · Serie 634 (modelli 0**)

EinPAS 15 Motore › 15.40 Impianto di scarico/post-trattamento dei gas di scarico › 15.40.51 Pompa/dosatore/ugello — Serie 382 (modelli 15*) · Serie 634 (modelli 0**)

Valido anche per motori/cambi: 457 9**

AR14.40-B-2025B

Check pneumatic working pressure at exhaust aftertreatment system metering device

12.02.16

Cumbustion engine 457.9 with Vehicle 382.15# #D, 634.0## #D with CODE MS5 (BlueTec 5)

Check pneumatic working pressure at exhaust aftertreatment system metering      
	device

W14.40-1384-06

1 Manometer

2 Measuring hose

3 Metering unit

4 Testing connection.

Removing and installing

Danger!

Risk of burns and scalding while working on AdBlue pipes and components connected to them. Risk of injury on skin and eyes at contact with AdBlue. Risk of poisoning from swallowing AdBlue

Only catch AdBlue in appropriate containers. Only start working on the exhaust gas after-treatment system after relieving the pressure.

AS14.40-B-0001-01A

Indications for applications, material properties and handling AdBlue

AH14.40-B-0001-01A

1

Switch-off the ignition

2

Open the access cover

3

Install the testing connection (4) in the compressed air inlet of the metering unit (3)

Only if a testing connection (4) is not yet installed.

The testing connection (4) can remain on the vehicle after testing.

AR14.40-B-2042B

4

Connect the measuring hose (2) on the gauge (1) and on the testing connection (4)

*360589002104

*360589002102

Danger!

Risk of accidents due to vehicle unintentional move when the engine is started. Risk of injury by pinching and burn by contact during the starting procedure or with the engine running

Assure vehicle against unintentional move. Utilize tight fitting and closed work clothes. Do not touch heated or running parts.

AS00.00-B-0005-01A

5

Start the engine

Let the engine running until the service pressure is formed in the compressed air reservoir.

6

Check the service pressure with the engine running

After engine shutdown, the metering unit will have to be cleaned with compressed air to avoid contamination

*BE14.40-B-1002-02B

7

Disconnect the measuring hose (2) at the gauge (1) and at the testing connection (4)

The testing connection (4) can remain on the vehicle after testing.

8

Close the engine access cover

Exhaust aftertreatment

Número

Denominação

Engine 457.9 with Code MS5

BE14.40-B-1002-02B

Nominal operating pressure value in the dosage unit compressed air inlet

bar

5,5

Check pneumatic working pressure at exhaust aftertreatment system metering      
	device
Check pneumatic working pressure at exhaust aftertreatment system metering      
	device

360 589 00 21 04

Manometer

360 589 00 21 02

Measuring hose