ap2000w2050h

Cooling and heating system - Check condition of radiator, lines and hoses

Vrsta ap · tema 20.00 · verzija 0106 · 2019-01-25

Vrijedi za: Engine 460.9 in model 963, 964 Engine 470.9, 471.9, 473.9, 936.9 in model 963, 964 Engine 934.9, 936.9 in model 967 Engine 936.9 (except 936.974) in model 956

Nije dostupno na jeziku „hr”; prikazano na jeziku Engleski.

Smještaj

Funkcijska skupina 1 Motor › 20 Hlađenje motora › 20.00 Opšte — Serija 460 (modeli 9**) · Serija 470 (modeli 9**) · Serija 471 (modeli 9**) · Serija 934 (modeli 9**) · Serija 936 (modeli 9**, 910, 912, 915, 916, 919, 923, 971, 972, 973, 975, 977, 991, 992) · Serija 956 · Serija 963 · Serija 964 · Serija 967

EinPAS 15 Engine › 15.25 Engine cooling system › 15.25.5 Coolant circuit, complete — Serija 460 (modeli 9**) · Serija 470 (modeli 9**) · Serija 471 (modeli 9**) · Serija 934 (modeli 9**) · Serija 936 (modeli 9**, 910, 912, 915, 916, 919, 923, 971, 972, 973, 975, 977, 991, 992) · Serija 956 · Serija 963 · Serija 964 · Serija 967

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.5 Air conditioning assembly — Serija 460 (modeli 9**) · Serija 470 (modeli 9**) · Serija 471 (modeli 9**) · Serija 934 (modeli 9**) · Serija 936 (modeli 9**, 910, 912, 915, 916, 919, 923, 971, 972, 973, 975, 977, 991, 992) · Serija 956 · Serija 963 · Serija 964 · Serija 967

Vrijedi i za motore/mjenjače: 473 9**

AP20.00-W-2050H

Cooling and heating system - Check condition of radiator, lines and hoses

16.01.2019

Engine

460.9 in model 963, 964

Engine

470.9, 471.9, 473.9, 936.9 in model 963, 964

Engine

934.9, 936.9 in model 967

Engine

936.9 (except 936.974) in model 956

Check

1

Check cooler for leak tightness and signs of any damage.

If damage is present,

repair or replace cooler.

Subject to separate repair order.

2

Check cooler and charge air cooler for external soiling.


The slats and the space between the radiator and charge air cooler must not be clogged with dirt.
Malfunctions may occur otherwise.

If dirty,

clean cooler and charge air cooler from outside.

Subject to separate repair order.

3

Check the additional radiator for leak tightness and that it is not damaged.

Model 956.### ## up to 247409

If damage is present,

repair or replace the additional radiator.

Subject to separate repair order.

4

Check additional cooler for external soiling.

Model 956.### ## up to 247409


The slats of the additional radiator must not be clogged with dirt.
Malfunctions may occur otherwise.

If dirty,

clean additional cooler from the outside.

Subject to separate repair order.

5

Check all lines and hoses on the cooling and heating system for undamaged condition, routing free of chafing and correct attachment, as well as for leak tightness at the connecting points.

If damage is present,

replace lines or hoses; if necessary, install lines and hoses correctly and ensure that they are attached properly.

Subject to separate repair order.