AR83.30-D-1780A

Drain air conditioning

7.1.96

MODELS 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H06) Air conditioning

Drain air conditioning

D83.30-0004-12

Position of the testing and filling valves

1 Test and charging valve on intake side

2 Pressure side testing and filling valve

Connecting

Danger!

Risk of explosion from welding or braizing work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant

Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or naked flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Do not carry out any repair work on the air conditioning system circuit unless the system is drained.

AS83.00-Z-0001-01A

Information for handling refrigerant R134a

All models with R134a refrigerant

AH83.30-N-0003-01A

1

Connect evacuation, preparation and charging unit

Connect the intake and pressure line for the evacuation, preparation and charging unit to the testing and charging valve on the intake side (1) and thrust

side (2)

*WE58.40-Z-1002-22A

Draining

2

Drain air conditioning

Slowly open valves of suction, treatment and filling device. Opening the valves slowly prevents the refrigerant from drawing compressor fluid out of the circuit along with it

3

Switch off evacuation, preparation and charging unit, remove intake and pressure line.

Workshop equipment

WE58.40-Z-1002-22A

Air conditioning service station