gf9130p2003mx

Heating mode, function

Type gf · topic 91.30 · version 0100 · 2002-09-19

Applies to: MODEL 240 with CODE (872) Electrically heated left and right rear seats with CODE (873) Electrically heated left and right front seats

Where it sits

Function group 3 Body › 91 Seats, bunks, restraint systems › 91.30 Seat heater, seat ventilation — Series 240

GF91.30-P-2003MX

Heating mode, function

27.5.02

MODEL 240
with CODE (872) Electrically heated left and right rear seats
with CODE (873) Electrically heated left and right front seats

Function requirements:

Term. 15R or term. 15 "ON"

Heating mode

The heated seats operating switch is designed as a button. This is read in by the

Left front door control module (N69/1)

Right front door control module (N69/2)

Left rear door control module (N69/3)

Right rear door control module (N69/4)

If the function conditions for the heated seats are fulfilled or the heated seats switched on then the corresponding message is sent cyclically to the CAN, as long as the switch is pressed.

Actuation

The heating resistors of the heated seats actuated by the

left front seat control module (N32/1)

right front seat control module (N32/2)

left rear seat control module (N32/11)

right rear seat control module (N32/13)

in accordance with the table below.

The heated seats can be switched on or off at any time by pressing a switch.

Function indicator

To actuate the function indicator the seat control module displays each heating stage as it is switched on over the CAN. Irrespective of this the door control module actuates the function indicator of the heated seats in accordance with the table shown below.

Heating stage

Heating capacity

Duty cycle (on)

Frequency

I

Low

27 % to 33 %

25 Hz to 30 Hz

II

middle

57 % to 63 %

25 Hz to 30 Hz

III

high

100 %

-

Operation of heated seat switch with function indicator

Switch operation

Heated seat operating condition following switch actuation

Function indicator (LED)

1st button actuation

Heating stage 3

High heating capacity

3 red LEDs

2nd button actuation

Heating stage 2

Average heater output

2 red LEDs

3rd button actuation

Heating stage 1

Low heating capacity

1 red LED

4th button actuation

OFF

-

-

5th. button actuation

Heating stage 3

High heating capacity

3 red LEDs

Terminate heater operation function

GF91.30-P-2004MX

Referenced documents