GF83.75-P-2000P | Residual engine heat utilization function | 11.5.06 |
MODEL 203.0 /2 /7 up to 31.5.01 with CODE (581) Automatic air conditioning
MODEL 203.0 /2 /7 as of 1.6.01
with CODE (581) Comfort automatic air conditioning
up to Model Year 8
MODEL 203.0 /2 /7
with CODE (450) Taxi version
with CODE (670) Residual engine heat utilization system (REST [MRA])
up to Model Year 8
Function
Residual engine heat utilization enables the vehicle to be heated even when the ignition is OFF.
To do so, the residual engine heat utilization system uses the residual heat from the engine and routes it into the passenger compartment via the blower motor (A32m1). The residual engine heat utilization is only possible when the ignition is switched off.
After pressing the REST button on the HEAT [HAU] control and operating unit (N18) or the AAC [KLA] control and operating unit (N22) (with code (450) Taxi version or with code (670) Residual engine heat utilization system (REST [MRA]) or at the comfort AAC (C-AAC [K-KLA]) control and operating unit (N22/7) the following program sequence is specified:
-----------------------------------------------------------------------------------------
Blend air flaps controlled
Coolant circulation pump (M13) ON
Blower motor (A32m1) automatically supplied with a control voltage of 30 %
Defroster and footwell flaps are automatically adjusted for approx. 30 seconds
Activated charcoal filter flap open (no activated charcoal filter operation possible in vehicles with comfort AAC (C-AAC [K-KLA]) control and operating unit (N22/7))
Footwell flaps 100 % OPEN
Defroster vent flaps 66 % OPEN
Fresh air vents 20 % open
Fresh air and air recirculation flap in fresh air position
-----------------------------------------------------------------------------------------
End of program
Repeated actuation of REST button
Expiration of the time function of approx. 30 min. (repeated actuation possible)
When battery voltage is less than 11 V, the LED on the REST button flashes on and off
Ignition On
During residual engine heat utilization only the REST button and the set point adjusters can be actuated, all other function keys are locked.
Heating pushbutton control unit, location/task | For vehicles without code (580) Air conditioning (or Tempmatic for USA) or without code (580) Automatic air conditioning or without code (581) Automatic air conditioning or without code (581) Comfort automatic air conditioning | ||
Control and operating unit for automatic air conditioning, location/task | For vehicles up to 31.5.01 with code (580) Air conditioning (or Tempmatic for USA) | ||
On vehicles as from 24.4.04 without code (581) Comfort automatic air conditioning | |||
Comfort automatic air conditioning control and operating unit, location/task | On vehicles up to 31.5.01 with code (581) Automatic air conditioning or as from 1.6.01 up to 23.4.04 with code (581) Comfort automatic air conditioning | ||
On vehicles as of 24.4.04 with code (581) Comfort automatic air conditioning | |||
Actuator motor automatic heater, location/task/function | For vehicles up to 23.4.04 without code (580) Air conditioning (or Tempmatic for USA) or without code (580) Automatic air conditioning or without code (581) Automatic air conditioning or without code (581) Comfort automatic air conditioning | ||
Actuator motors for automatic air conditioning, location/task/function | For vehicles up to 31.5.01 with code (580) Air conditioning (or Tempmatic for USA) | ||
Actuator motors for comfort automatic air conditioning, location/task/function | On vehicles up to 31.5.01 with code (581) Automatic air conditioning or as from 1.6.01 with code (581) Comfort automatic air conditioning | ||
Blower motor, location/task/function | |||
Heating system heat exchanger, location/task/function | |||
Heater water circulation pump, location/task/function |
Referenced documents
- gf8310p2140p Blower motor , location/task/function
- gf8320p2108p Heating system heat exchanger, location/task/function
- gf8320p2109p Heating water circulation pump, location/task/function
- gf8320p2120pp Heating pushbutton control unit, location/task
- gf8325p2180p Automatic heater actuator motors location/task/function
- gf8340p2180pp Control and operating unit for automatic air conditioning, location/task
- gf8340p2180pq Control and operating unit for automatic air conditioning, location/task
- gf8340p2181pp Control and operating unit comfort automatic air conditioning location/task
- gf8340p2181pq Control and operating unit comfort automatic air conditioning location/task
- gf8340p2182p Actuator motors for automatic air conditioning, location/task/function
- gf8340p2183p Actuator motors for comfort automatic air conditioning, location/task/function