GF83.70-S-2002SA | Terminate heater mode, function | 20.12.03 |
MODEL 639.813
with CODE (HZ1) Warm air auxiliary heater (Westfalia)
with CODE (ZK7) Motor caravan "Marco Polo"
N54.21-2106-11
1 "Fresh water level" display
2 "Battery mode" display
3 Multiple display for "Interior temperature", "Switch-on time", "Refrigerator box temperature" and "Remaining time"
4 "230-V supply voltage and charger" display
5 "Stationary heating mode" display
6 "Refrigerator box mode" display
7 "Additional battery capacity" display
8 "Stationary heater switch-on times" display
9 "Timer" display
10 "Waste water level" display
11 "Outside temperature" button
12 "Stationary heater switch-on times" button
13 "ON/OFF" button for refrigerator box, stationary heater and timer
14 "Increase" button
15 "Decrease" button
16 "Refrigerator box temperature" button
17 "Stationary heater heating level" button
18 "Additional battery voltage" button
N10/16 COU [ZBE] control unit
Operation of the heater can be switched directly on the COU control unit (N10/16) for the heater unit (A7) or at a preset timeFuel delivery is stopped immediately by shutting off the warm air STH fuel metering pump (M46/2). To cool down the heater unit (A7) the hot air blower fan motor (A7m1) is activated for approx. t = 4 min. (cold blow phase). The glow pin (A7r1) is actuated for t = 40 s during the cold blow phase to clean it from possible combustion residues.When the cold blow phase is completed, all heater unit (A7) components are switched off
-----------------------------------------------------------------------------------------
Deactivate heater mode from the standby mode
If fuel is not supplied until the heater unit (A7) is deactivated or the heater unit (A7) is in the stage "OFF", the heater unit (A7) is switched off immediately without activating the hot air blower fan motor (A7m1) (cold blow phase).
Manual mode without timer
Deactivate heater unit (A7)
The "ON/OFF" button for the refrigerator box, the stationary heater and the timer (13) and the "Stationary heater heating level" (17) button must be pressed simultaneously. Activation is indicated in the display of the COU control unit (N10/16) by extinguishing of the "Stationary heater mode" display (5).
-----------------------------------------------------------------------------------------
Program timer
Switch timer off
Press the "Stationary heater switch-on times" (12) button and the "ON/OFF" button for the refrigerator box, the stationary heater and the timer (13) simultaneously until the "Stationary heater mode" (5) indicator in the COU control unit (N10/16) display goes off.
Heater unit (A7) switch-off malfunction
A shutoff takes place if one of the following conditions exists:
If voltage (U < 10.5 V) is too low or too high (U > 16 V) the heater unit (A7) is switched off after 20 s
When the overheating and flame sensor unit (A7r3) is defective or the electrical line to the overheating and flame sensor unit (A7r3) is interrupted, the heater unit (A7) is started and only switched off during the staring phase
If the hot air blower fan motor (A7m1) does not start or if the speed deviates min. 10 %, the heater unit (A7) is switched off after = 30 s
After a malfunction switch-off, the actuation of the warm air STH fuel metering pump (M46/2) is interrupted and the hot air blower fan motor (A7m1) continues to run for
t = 4 min.
Central operating unit (ZBE) control unit, location/task/design | |||
Glow pin, location/task | |||
Heat exchanger, location/task/design | |||
Fuel metering pump, location/task/design | |||
Combustion air/hot air blower, location/task/design | |||
Burner insert with burner tube, location/task/design | |||
Auxiliary heating control unit (ZHE), location/task | |||
Overheating and flame sensor, location/task | |||
Auxiliary heater unit (ZHE), location/task/design |
Referenced documents
- gf5421s4400s Central operating unit (ZBE) control unit, location/task/design
- gf8370s4005s Glow pin, location/task
- gf8370s4017s Heat exchanger, location/task/design
- gf8370s4023sa Fuel metering pump, location/task/design
- gf8370s4027s Combustion air/hot air blower, location/task/design
- gf8370s4029s Burner insert with burner tube, location/task/design
- gf8370s4105s Auxiliary heater control unit (ZHE), location/task
- gf8370s4125s Overheating and flame sensor, location/task
- gf8370s4130s Auxiliary heater unit (ZHE), location/task/design