gf8370s2002sa

Terminate heater mode, function

Type gf · topic 83.70 · version 0102 · 2005-09-21

Applies to: MODEL 639.813 with CODE (HZ1) Warm air auxiliary heater (Westfalia) with CODE (ZK7) Motor caravan "Marco Polo"

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 639 (models 813)

GF83.70-S-2002SA

Terminate heater mode, function

20.12.03

MODEL 639.813
with CODE (HZ1) Warm air auxiliary heater (Westfalia)
with CODE (ZK7) Motor caravan "Marco Polo"

Terminate heater mode, function

N54.21-2106-11

1 "Fresh water level" display

2 "Battery mode" display

3 Multiple display for "Interior temperature", "Switch-on time", "Refrigerator box temperature" and "Remaining time"

4 "230-V supply voltage and charger" display

5 "Stationary heating mode" display

6 "Refrigerator box mode" display

7 "Additional battery capacity" display

8 "Stationary heater switch-on times" display

9 "Timer" display

10 "Waste water level" display

11 "Outside temperature" button

12 "Stationary heater switch-on times" button

13 "ON/OFF" button for refrigerator box, stationary heater and timer

14 "Increase" button

15 "Decrease" button

16 "Refrigerator box temperature" button

17 "Stationary heater heating level" button

18 "Additional battery voltage" button

N10/16 COU [ZBE] control unit

Operation of the heater can be switched directly on the COU control unit (N10/16) for the heater unit (A7) or at a preset timeFuel delivery is stopped immediately by shutting off the warm air STH fuel metering pump (M46/2). To cool down the heater unit (A7) the hot air blower fan motor (A7m1) is activated for approx. t = 4 min. (cold blow phase). The glow pin (A7r1) is actuated for t = 40 s during the cold blow phase to clean it from possible combustion residues.When the cold blow phase is completed, all heater unit (A7) components are switched off

-----------------------------------------------------------------------------------------

Deactivate heater mode from the standby mode

If fuel is not supplied until the heater unit (A7) is deactivated or the heater unit (A7) is in the stage "OFF", the heater unit (A7) is switched off immediately without activating the hot air blower fan motor (A7m1) (cold blow phase).

Manual mode without timer

Deactivate heater unit (A7)

The "ON/OFF" button for the refrigerator box, the stationary heater and the timer (13) and the "Stationary heater heating level" (17) button must be pressed simultaneously. Activation is indicated in the display of the COU control unit (N10/16) by extinguishing of the "Stationary heater mode" display (5).

-----------------------------------------------------------------------------------------

Program timer

Switch timer off

Press the "Stationary heater switch-on times" (12) button and the "ON/OFF" button for the refrigerator box, the stationary heater and the timer (13) simultaneously until the "Stationary heater mode" (5) indicator in the COU control unit (N10/16) display goes off.

Heater unit (A7) switch-off malfunction

A shutoff takes place if one of the following conditions exists:

If voltage (U < 10.5 V) is too low or too high (U > 16 V) the heater unit (A7) is switched off after 20 s

When the overheating and flame sensor unit (A7r3) is defective or the electrical line to the overheating and flame sensor unit (A7r3) is interrupted, the heater unit (A7) is started and only switched off during the staring phase

If the hot air blower fan motor (A7m1) does not start or if the speed deviates min. 10 %, the heater unit (A7) is switched off after = 30 s

After a malfunction switch-off, the actuation of the warm air STH fuel metering pump (M46/2) is interrupted and the hot air blower fan motor (A7m1) continues to run for
t = 4 min.

Central operating unit (ZBE) control unit, location/task/design

GF54.21-S-4400S

Glow pin, location/task

GF83.70-S-4005S

Heat exchanger, location/task/design

GF83.70-S-4017S

Fuel metering pump, location/task/design

GF83.70-S-4023SA

Combustion air/hot air blower, location/task/design

GF83.70-S-4027S

Burner insert with burner tube, location/task/design

GF83.70-S-4029S

Auxiliary heating control unit (ZHE), location/task

GF83.70-S-4105S

Overheating and flame sensor, location/task

GF83.70-S-4125S

Auxiliary heater unit (ZHE), location/task/design

GF83.70-S-4130S

Referenced documents