gf8370d2002rb

Terminate heater operation function

Type gf · topic 83.70 · version 0100 · 2013-11-09

Applies to: MODEL 909 with CODE HZ9 (Heater booster, diesel) without CODE H13 (Additional heat exchanger in load compartment) without CODE HZ5 (10 kW warm water auxiliary heater with timer)

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 909

GF83.70-D-2002RB

Terminate heater operation function

25.10.13

MODEL

909

with CODE HZ9 (Heater booster, diesel)

without CODE H13 (Additional heat exchanger in load compartment)

without CODE HZ5 (10 kW warm water auxiliary heater with timer)

On vehicles with CODE HZ9 (Heater booster, diesel), the heater booster (HB) heating mode is ended after a change in status from "Circuit 61 ON" to "Circuit 61 OFF" or by renewed operation of the air conditioning, heater booster, residual heat rotary switch in the climate control control and operating unit (A81) with CODE HH9 (Regulated air conditioning (Tempmatic)) or the heater booster rotary switch in the climate control control and operating unit, except CODE HH9 (Regulated air conditioning (Tempmatic)). The signal from the air conditioning, heater booster, residual heat rotary switch in the climate control control and operating unit with CODE HH9 (Regulated air conditioning (Tempmatic)) or the heater booster rotary switch in the climate control control and operating unit, except CODE HH9 (Regulated air conditioning (Tempmatic)) is sent over a discrete line to the hot water auxiliary heater control unit (E90).

The air conditioning, heater booster, residual heat rotary switch in the climate control control and operating unit with CODE HH9 (Regulated air conditioning (Tempmatic)) or the heater booster rotary switch in the climate control control and operating unit, except CODE HH9 (Regulated air conditioning (Tempmatic)) has a "memory function" (automatic triggering of heating mode in heater booster heater unit). The "memory function" remains active until it is deactivated again by operating the air conditioning, heater booster, residual heat rotary switch in the climate control control and operating unit with CODE HH9 (Regulated air conditioning (Tempmatic)) or the heater booster rotary switch in the climate control control and operating unit, except CODE HH9 (Regulated air conditioning (Tempmatic)).

The hot water auxiliary heater control unit reads in the signal directly from the climate control control and operating unit and then interrupts actuation of the following components required for the heater booster heater unit heating mode:

Blower motor (E90m46) of the heater booster combustion air blower, for combustion air supply

Glow pin (E90r18), for preheating burner housing and for igniting fuel/air mixture

Metering pump (M61), to supply the fuel

Circulation pump (M51), for circulating the coolant

After the heating mode has been shut off, the heater booster heater unit switches to run-on mode. In run-on mode, the hot water auxiliary heater control unit actuates the blower motor for the heater booster combustion air blower and the climate control control and operating unit actuates the circulation pump so that the combustion chamber with downpipe on the heater booster heater unit is cooled down by the generated air suction and the heater booster heater unit's heat exchanger by the blowby coolant.

Tempmatic (TM) control and operating unit, component description

With code HH9 (Regulated air conditioning (Tempmatic))
A81

GF83.40-D-4015R

Heater operating unit component description

Except CODE HH9 (Regulated air conditioning (Tempmatic))
A81

GF83.20-D-4005R

ZUH control unit, component description

E90

GF83.70-D-4215R

ZUH heater, component description

E90b96, E90b97, E90b98, E90m46, E90r18

GF83.70-D-4210R

Coolant circulation pump component description

M51

GF83.20-D-4010R

Component description for stationary heater/heater booster fuel metering pump

M61

GF83.70-D-4069R

Referenced documents