GF83.70-D-2002JK | End heater operation, function | 10.11.04 |
MODEL 903.622
with CODE (Z29) "James Cook" touring camper, NAFTA
with CODE (ZU8) National version for USA
D54.21-1130-11
5 "Stationary heater operation" display
11 "Outside temperature" button
12 "Stationary heater switch-on times" button
13 "ON/OFF" button for refrigerator box, stationary heater and timer
16 "Stationary heater heating level" button
A97 Camper operating and display unit
The button "outside temperature" (11) is nonfunctional. The outside temperature can be requested via the instrument cluster (P15) and it will also be displayed there.
The heating mode is switched off directly at the camper operating and display unit (A97) of the hot air auxiliary heater unit or by means of preselection. The fuel supply is stopped immediately by switching off the metering pump (M16). To cool down the hot air auxiliary heater unit, activate the blower motor (E18m44) for
t = 4 mins. (cold blowing phase). To clean possible combustion residues, the glow pin (E18r19) is actuated during the cold blowing phase for t = 40 seconds.
When the cold blowing phase is complete, all components of the hot air auxiliary heater unit are switched off.
The hot air auxiliary heater unit runs for a maximum of
t = 120 mins. after activation
-----------------------------------------------------------------------------------------
Deactivate heater operation from the standby mode
If there is still no fuel delivery by the time the warm air auxiliary heater unit is deactivated or if the hot air auxiliary heater unit is in the control level "OFF", the hot air auxiliary heater unit is switched off immediately, without the blower motor (E18m44) being activated (cold blowing phase).
Manual operation without timer
Deactivate the hot air auxiliary heater unit
The "ON/OFF" button for the refrigerator box, the stationary heater and the timer (13) and the "stationary heater heating level" button (16) must be pressed simultaneously. Deactivation is indicated on the camper operating and display unit (A97) by the "stationary heater operation" indicator (5) going off.
-----------------------------------------------------------------------------------------
Program timer
Switch timer off
Press the "stationary heater switch-on times" button (12) and the "ON/OFF" button for the refrigerator box, the stationary heater and the timer (13) simultaneously until the "stationary heater operation" indicator (5) in the camper operating and display unit (A97) goes off.
Fault shutoff of the hot air auxiliary heater unit
A shutoff takes place if one of the following conditions exists:
If the voltage level drops below 10.5 V (undervoltage) or the voltage level exceeds 16 V (overvoltage), the hot air auxiliary heater unit is shut off after t = 20 seconds.
If the overheating sensor (E18b95) and the flame sensor are defective (E18b96) or if the electrical line is interrupted, the hot air auxiliary heater unit is activated and only switched off during the start-up phase.
If the hot air auxiliary heater unit does not start or the speed differs by more than 10 %, the hot air auxiliary heater unit is shut off after t = 30 seconds.
After a fault shutoff, the actuation of the metering pump (M16) is canceled and the blower motor (E18m44) runs for
t = 4 mins.
Battery disconnect switch, location / task | |||
Central operating unit (ZBE) control unit, location/task/design | |||
Glow pin, location/task | |||
Heat exchanger, location/task/design | |||
Fuel metering pump, location/task/design | |||
Combustion air/hot air blower, location/task/design | |||
Burner insert with burner tube, location/task/design | |||
Auxiliary heater control unit (ZHE), location/task | |||
Overheating and flame sensor, location/task | |||
In-car temperature sensor location/task | |||
Auxiliary heater unit (ZHE), location/task/design |
Referenced documents
- gf5410d4101jk Battery disconnect switch, location / task
- gf5421d4400jk Central operating unit (COU) control unit, location/task/design
- gf8370d4005jk Glow pin, location/task
- gf8370d4017jk Heat exchanger, location/task/design
- gf8370d4023jk Fuel metering pump, location/task/design
- gf8370d4027jk Combustion air/hot air blower, location/task/design
- gf8370d4029jk Burner insert with burner tube, location/task/design
- gf8370d4105jk Auxiliary heater control unit (ZHE), location/task
- gf8370d4125jk Overheating and flame sensor, location/task
- gf8370d4127jk In-car temperature sensor location/task
- gf8370d4130jk Auxiliary heater unit (ZHE), location/task/design