Refrigerant pressure sensor, component description

Type gf · topic 83.40 · version 0102 · 2008-04-11

Applies to: MODEL 251.1 /0 up to Model Year 8

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 251 (models 0**, 1**)

GF83.40-P-2193RT

Refrigerant pressure sensor, component description

23.5.05

MODEL 251.1 /0 up to Model Year 8

Refrigerant pressure sensor, component description

P83.40-3086-76

B12 Refrigerant pressure sensor

Location

The refrigerant pressure sensor is located in the engine compartment at the front left on the high pressure line between the refrigerant compressor (A9) and condenser.

Task

The refrigerant pressure sensor records the refrigerant pressure. The reading is read in by the AAC control and operating unit (N22) or comfort AAC control and operating unit (N22/7).

Detecting the refrigerant pressure

The refrigerant pressure sensor records the refrigerant pressure and forwards the determined value over the front SAM control unit (N10) and CAN-B to the AAC [KLA] control and operating unit or the comfort AAC [KLA] control and operating unit. This value is compared against a stored pressure curve.

The refrigerant pressure sensor operates in a pressure value range of 0 to 35 bar.

Left refrigerant compressor cutout

The refrigerant compressor is cut out if the following values are given.

Refrigerant pressure < 1.7 bar = Refrigerant compressor OFF

Refrigerant pressure > 30 bar = Refrigerant compressor OFF

Cut-in of electric suction fan engine and AC with integrated control (M4/7)

The electric suction fan engine and AC with integrated control is actuated at the following values:

Refrigerant pressure < 12 bar = Suction fan OFF

Refrigerant pressure > 20 bar = Suction fan ON (100 %)

Refrigerant pressure 12 to 20 bar = Continuously linear speed increase of suction fan
(20 to 100 %)

The following values apply to hot countries:

Refrigerant pressure < 10 bar = Suction fan OFF

Refrigerant pressure > 18 bar = Suction fan ON (100 %)

Refrigerant pressure 10 to 18 bar = Continuously linear speed increase of suction fan
(20 to 100 %)