gf8340p2003a

CNS/ICS operating and display unit with control module position/function

Type gf · topic 83.40 · version 0103 · 2000-01-26

Applies to: MODEL 210 with CODE (498) Japanese version MODEL 140 up to 30.3.97 with CODE (498) Japanese version with CODE (350b) Information and Communication System (ICS) MODEL 140 as of 1.4.97 with CODE (498) Japanese version

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 140 · Series 210

GF83.40-P-2003A

CNS/ICS operating and display unit with control module position/function

18.8.97

MODEL 210 with CODE (498) Japanese version

MODEL 140 up to 30.3.97
with CODE (498) Japanese version
with CODE (350b) Information and Communication System (ICS)

MODEL 140 as of 1.4.97 with CODE (498) Japanese version

CNS/ICS operating and display unit with control module position/function

P83.40-0247-06

Automatic pushbutton

Warm temperature pushbutton

Cold temperature pushbutton

Defrost pushbutton

Recirculated air pushbutton

Activated charcoal filter pushbutton

Air distributor pushbutton

Rest pushbutton

Blower pushbutton

EC pushbutton

Function

The operating/display unit with control module (A40) permits performance of adjustments required by the driver, such as

Passenger compartment temperature by pressing the warm/cold pushbuttons ,

Manual air quantity by pressing the pushbutton +/-

Manual air distribution by pressing the air distribution pushbutton )

Recirculated air by pressing the pushbutton

Activation of residual engine heat recirculation, with ignition off, by pressing the

pushbutton

Switching off cooling by pressing the pushbutton

Automatic air distribution and blower speed by pressing the pushbutton

Defrosting function by pressing the pushbutton

Switching on the activated charcoal filter by pressing the pushbutton

The driver will be shown these adjustments on the display.

Regulation and control of the system, as well as the adjustments made by the driver is performed by the AAC/CNS/ICS control module (N22/1).

The AAC/CNS/ICS control module (N22/1) can be diagnosed so that faults arising are stored in a fault memory, which can be read out on-board or with the aid of the Hand-Held Tester

Blower pushbutton Location/task/function

GF83.40-P-2144A

Air distribution pushbutton Location/task/function

GF83.40-P-2159A

Recirculated air pushbutton Location/task/function

GF83.40-P-2145A

EC pushbutton Location/task/function

GF83.40-P-2146A

Warm temperature pushbutton Location/task/function

GF83.40-P-2160A

Automatic pushbutton Location/task/function

GF83.40-P-2147A

Rest pushbutton Location/task/function

GF83.40-P-2148A

Cold temperature pushbutton Location/task/function

GF83.40-P-2161A

Activated charcoal filter pushbutton Location/task/function

Model 140 with Code 306a only

GF83.40-P-2149A

Defrost pushbutton Location/task/function

GF83.40-P-2139A

Display Location/task/function

GF83.40-P-2150A

AAC/CNS/ICS control module Location/task/function

GF83.40-P-2168A

Referenced documents