gf8330p2000e

Tempmatic air conditioning pushbutton control module position/function

Type gf · topic 83.30 · version 0104 · 2000-01-26

Applies to: MODEL 202 as of 1.9.95, 208 with CODE (580) Air conditioning or Tempmatic for USA

Where it sits

Function group 3 Body › 83 Climate control › 83.30 Air conditioning — Series 202 · Series 208

GF83.30-P-2000E

Tempmatic air conditioning pushbutton control module position/function

11.12.97

MODEL 202 as of 1.9.95,
208 with CODE (580) Air conditioning or Tempmatic for USA

Tempmatic air conditioning pushbutton control module position/function

P83.30-2041-11

Shown on model 202

1 Temperature selection wheels

2 Blower switch

3 Air distribution switch

Recirculated air pushbutton

EC push button

Rest push button (in model 202 up to 08/97 only with Code 450, as of 09/97 serial equipment)

N19/ Tempmatic (Tempmatic A/C) control and operating module

Function

The control and operating module (N19) of the Tempmatic (Tempmatic A/C) permits performance of adjustments required by the driver, such as:

Temperature by using the temperature selection wheels (1)

Air quantity by using the blower switch (2)

Air distribution by using the air distribution switch (3)

Recirculated air by pressing the recirculated air pushbutton ()

Activation of residual engine heat recirculation, with ignition off, by pressing the Rest pushbutton

( )

- Switching off cooling by pressing the EC pushbutton ( )

Furthermore the control module integrated into the control and operating (N19) module takes over regulation and control of systems, such as:

comparison of the preselected / actual temperatures and adjustment of the air output temperature to the air outlets

automatic switching from fresh air to recirculated air (except A208.4 with open soft top)

electrical actuation of the refrigerant compressor

actuation of the auxiliary ventilator

The control and operation module (N19) can be diagnosed so that faults arising are stored in a fault memory, which can be read out with the aid of the HHT.

When changing the control and operating module (N19) a variant coding should be performed with the aid of the Hand-Held Tester or DMNL air conditioning.

Blower switch Location/task/function

GF83.25-P-2104A

Air distribution switch Location/task/function

GF83.25-P-2103A

Temperature selection wheel Location/task/function

GF83.25-P-2105A

Recirculated air pushbutton Location/task/function

GF83.40-P-2145A

EC pushbutton Location/task/function

GF83.40-P-2146E

Rest pushbutton Location/task/function

Model 202 up to 08/97 with Code 450 only

Models 208, 202 as of 09/97

GF83.40-P-2148A