GF83.30-P-2000E | Tempmatic air conditioning pushbutton control module position/function | 11.12.97 |
MODEL 202 as of 1.9.95,
208 with CODE (580) Air conditioning or Tempmatic for USA
P83.30-2041-11
Shown on model 202
1 Temperature selection wheels
2 Blower switch
3 Air distribution switch
Recirculated air pushbutton
EC push button
Rest push button (in model 202 up to 08/97 only with Code 450, as of 09/97 serial equipment)
N19/ Tempmatic (Tempmatic A/C) control and operating module
Function
The control and operating module (N19) of the Tempmatic (Tempmatic A/C) permits performance of adjustments required by the driver, such as:
Temperature by using the temperature selection wheels (1)
Air quantity by using the blower switch (2)
Air distribution by using the air distribution switch (3)
Recirculated air by pressing the recirculated air pushbutton ()
Activation of residual engine heat recirculation, with ignition off, by pressing the Rest pushbutton
( )
- Switching off cooling by pressing the EC pushbutton ( )
Furthermore the control module integrated into the control and operating (N19) module takes over regulation and control of systems, such as:
comparison of the preselected / actual temperatures and adjustment of the air output temperature to the air outlets
automatic switching from fresh air to recirculated air (except A208.4 with open soft top)
electrical actuation of the refrigerant compressor
actuation of the auxiliary ventilator
The control and operation module (N19) can be diagnosed so that faults arising are stored in a fault memory, which can be read out with the aid of the HHT.
When changing the control and operating module (N19) a variant coding should be performed with the aid of the Hand-Held Tester or DMNL air conditioning.
Blower switch Location/task/function | |||
Air distribution switch Location/task/function | |||
Temperature selection wheel Location/task/function | |||
Recirculated air pushbutton Location/task/function | |||
EC pushbutton Location/task/function | |||
Rest pushbutton Location/task/function | Model 202 up to 08/97 with Code 450 only Models 208, 202 as of 09/97 |
Referenced documents
- gf8325p2103a Air distribution switch, location/purpose/function
- gf8325p2104a Blower switch, location/purpose/function
- gf8325p2105a Temperature selector, location/purpose/function
- gf8340p2145a Recirculating air pushbutton, position/task/function
- gf8340p2146e EC button, location / task / function
- gf8340p2148a REST pushbutton, location/purpose/function