gf8310p2191rt

Emissions sensor, component description

Type gf · topic 83.10 · version 0102 · 2008-04-01

Applies to: MODEL 251.1 /0 with CODE (581) Comfort automatic air conditioning up to Model Year 8

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 251 (models 0**, 1**)

GF83.10-P-2191RT

Emissions sensor, component description

31.5.05

MODEL 251.1 /0
with CODE (581) Comfort automatic air conditioning
up to Model Year 8

Emissions sensor, component description

P83.10-2541-06

B31 Emissions sensor

Location

The emissions sensor is installed on the right firewall.

Task

The values of the emissions sensor are processed by the front air conditioning. It senses the concentration of the air pollutants carbon monoxide and nitrogen oxide. The comfort AAC [KLA] control and operating unit (N22/7) uses the measured values of the emissions sensor to control the recirculated air.

If the air pollutant concentration is too high, only the inside air is recirculated and the supply of outside air is prevented.

This function is not available with A/C OFF.

Function

The emissions sensor operates reactively:

The air recirculation flap is not closed until after the sensor has detected an increase of the CO and NOx values. Although this only takes a few seconds, part of the pollutants might have already reached the interior compartment during this time. To prevent this from happening, the activated charcoal filter retains the pollutants until the recirculation door is closed.