GF83.10-P-2001E | Vacuum system, function | 11.12.97 |
MODEL 202 up to 31.8.95 with CODE (305a) Dust filter
MODEL 202 as of 1.9.95 except CODE (581a) Air conditioning (automatic)
MODEL 208 except CODE (581a) Air conditioning (automatic)
MODEL 170
P83.10-2006-06
35 Cockpit separation point
36 Vacuum valve block
44 Fresh/recirculated air flap vacuum element
Y13 Fresh/recirculated air flap switchover valve
Function
The HEAT and Tempmatic A/C vacuum system serves for control of the fresh/recirculated air flap.
The vacuum is connected to the fresh/recirculated air flap switchover valve (Y13) via the valve block (36) and the cockpit separation point (35). The fresh/recirculated air flap switchover valve (Y13) is opened by pressing the recirculated air button
( ) on the pushbutton control module whereby the fresh/recirculated air flap switchover valve is actuated via the fresh/recirculated air flap valve vacuum element (44).
Referenced documents
- gf8310p2155e Switchover valve, location/purpose/function
- gf8310p2159a Vacuum element for fresh air/recirculated air flap, location/purpose/function