gf8295p3003a

Data from airbag control module for TELE AID, function

Type gf · topic 82.95 · version 0104 · 2001-02-08

Applies to: MODEL 129, 202, 208.3, 210 as of 1.6.98, 215, 220 with CODE (347) TELE AID emergency call system (D2B) MODEL 140, 210 up to 31.5.98 with CODE (348) TELE AID emergency call system MODEL 140, 202, 210, 220 with CODE (930) Taxi emergency call

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.95 Emergency call system — Series 129 · Series 140 · Series 202 · Series 208 (models 3**) · Series 210 · Series 215 · Series 220

GF82.95-P-3003A

Data from airbag control module for TELE AID, function

30.4.97

MODEL 129, 202, 208.3, 210 as of 1.6.98,
215, 220 with CODE (347) TELE AID emergency call system (D2B)

MODEL 140,
210 up to 31.5.98 with CODE (348) TELE AID emergency call system

MODEL 140, 202, 210, 220 with CODE (930) Taxi emergency call

The emergency call system control module (TELE AID, A35/8) receives the following messages from the emergency tensioning retractor control module with airbag (AB) (N2/2, not in models 215, 220) or from the restraint system control module (N2/7, Models 215, 220) :

B1: Readiness

B2: Test signal for function check

B3: Front end collision, emergency tensioning retractor activated

B4: Rear end collision, emergency tensioning retractor activated.

B5: Front end collision, airbag triggered

B6: Side collision, side airbag triggered

After TELE AID is switched on, the emergency call system control module (TELE AID, A35/8) waits for a readiness message from the emergency tensioning retractor control module with airbag (AB) (N2/2, not in models 215, 220) or from the restraint system control module (N2/7, models 215, 220) If this message is not received within 30 s the indicator lamp in the TELE AID emergency call pushbutton switch (S93/3) comes on and the error is stored in the DTC memory.Ready messages coming in later are still accepted, the status indicator lamp goes also out.

After the ready message is received the emergency call system control module (TELE AID, A35/8) expects further ready messages every 500 ms.If this is not accomplished for more than 3 s, the status indicator lamp in the TELE AID emergency call pushbutton switch (S93/3) comes on and the error is stored in the DTC memory of the emergency call control module (TELE AID, A35/8) . Later incoming messages are still received.

A TELE AID emergency call is automatically actuated when a crash message is received twice within one second in the emergency call system control module (TELE AID, A35/8) .

When a crash message is received once the status indicator lamp in the TELE AID pushbutton switch (S93/3) comes on.This is entered into the DTC memory of the emergency call control module (TELE AID, A35/8), later incoming messages are, however, still received.

TELE AID switch-on/switch-off characteristics, function

GF82.95-P-2000A

Status indicator (indicator lamp), function

GF82.95-P-2002A

Emergency call actuation, function

GF82.95-P-2003A

Emergency call telegram generation, function

GF82.95-P-2004A

TELE AID control module, location/purpose/design/function

GF82.95-P-4100A

TELE AID emergency call pushbutton switch, location/purpose/design/function

GF82.95-P-4101A