gf8295p2000a

TELE AID switch-on/switch-off characteristics, function

Type gf · topic 82.95 · version 0104 · 2001-02-08

Applies to: MODEL 129, 202, 208.3, 210 as of 1.6.98, 215, 220 with CODE (347) TELE AID emergency call system (D2B) MODEL 140, 210 up to 31.5.98 with CODE (348) TELE AID emergency call system MODEL 140, 202, 210, 220 with CODE (930) Taxi emergency call

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.95 Emergency call system — Series 129 · Series 140 · Series 202 · Series 208 (models 3**) · Series 210 · Series 215 · Series 220

GF82.95-P-2000A

TELE AID switch-on/switch-off characteristics, function

24.4.97

MODEL 129, 202, 208.3, 210 as of 1.6.98,
215, 220 with CODE (347) TELE AID emergency call system (D2B)

MODEL 140,
210 up to 31.5.98 with CODE (348) TELE AID emergency call system

MODEL 140, 202, 210, 220 with CODE (930) Taxi emergency call

Switch-on characteristics

The TELE AID system is switched on by turning the starter switch (S2) to circuit 15R. The switch-on procedure is indicated by the indicator lamp (4 s) coming on in the TELE AID pushbutton switch (S93/3) . Then the system is ready for operation.

After switch-on the emergency call system control module (TELE AID, A35/8) activates the CTEL transmitter and receiver (A35) and waits for readiness confirmation of the

emergency tensioning retractor control module (ETR) with airbag (AB) (N2/2)

or depending on vehicle model the

restraint system control module (N2/7).

Switch off characteristics

TELE AID is switched off when circuit 15R of the starter switch (S2) is switched off, an emergency call is not activated and the telephone is set to shut-off delay.

The telephone system can be set to shut-off delay so that it is possible to continue a call for a certain time even with circuit 15R: OFF.

For control of the telephone system TELE AID remains also active during the telephone shut-off delay, however, it is not possible to trigger an emergency call .


During an emergency call TELE AID is not switched off before the emergency call is terminated.

If an authorization is accomplished while switching off circuit 15R it is interrupted and TELE AID then switched off.

TELE AID block diagram

Models 129, 140 except 140.063/07 202, 208.3, 210, 220 with code 347/348, Model 140 with code 930

GF82.95-P-0001-02A

Models 202, 210, 220 with code 930

GF82.95-P-0001-02B

Authorization, function

GF82.95-P-2001A

Status indicator (indicator lamp), function

GF82.95-P-2002A

TELE AID control module, location/purpose/design/function

GF82.95-P-4100A

TELE AID emergency call pushbutton switch, location/purpose/design/function

GF82.95-P-4101A

Referenced documents