P82.35-2205-06
1 Ambient temperature
2 Engine running (circuit 61)
3 Washer fluid hose heater/washer nozzle heater
4 Terminal 15 ON
B14 Ambient temperature display temperature sensor
G2 Generator
N10/1 Front SAM control module with fuse and relay module
N73 EIS control module
R2/1 Washer nozzle heater
R2/11 Washer nozzle hose heater
CAN B CAN class B
Washer nozzles and washer nozzle hose heaters, function
The washer nozzle heater (R2/1) and washer nozzle hose heater (R2/11) are switched on automatically when:
Circuit 61 ON (engine running) and
an outside temperature less than 5 °C is detected.
Switch off is accomplished automatically when:
Circuit 61 OFF (engine OFF) or
an outside temperature of more than 8 °C is detected.
In the event of no or implausible values (outside temperature, circuit 61) the heating elements are not actuated.
Actuation of heating elements
All heating elements for the washer nozzle heater (R2/1) and washer nozzle hose heater (R2/11) are connected in parallel.
The washer nozzle heater (R2/1) and washer nozzle hose heater (R2/11) are actuated directly by the front SAM control module with fuse and relay module (N10/1). During this process, the front SAM control module with fuse and relay module (N10/1) switches circuit 30 to the heating elements.
Required data
The outside temperature is measured by the outside temperature display temperature sensor (B14). The front SAM control module with fuse and relay module (N10/1) reads in the outside temperature display temperature sensor (B14) directly.
The status of circuit 61 (alternator (G2)) is also read in directly by the front SAM control module with fuse and relay module (N10/1).
Referenced documents
- gf5421p4108q Front SAM control unit with fuse and relay module, location / task / design