gf8235p3003q

Washer nozzles/washer nozzle hose heater, function

Type gf · topic 82.35 · version 0102 · 2003-04-28

Applies to: MODELS 209.3 /4

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.35 Windshield washing system — Series 209 (models 3**, 4**)

GF82.35-P-3003Q

Washer nozzles/washer nozzle hose heater, function

7.3.02

MODELS 209.3 /4

Washer nozzles/washer nozzle hose heater, function

P82.35-2205-06

1 Ambient temperature

2 Engine running (circuit 61)

3 Washer fluid hose heater/washer nozzle heater

4 Terminal 15 ON

B14 Ambient temperature display temperature sensor

G2 Generator

N10/1 Front SAM control module with fuse and relay module

N73 EIS control module

R2/1 Washer nozzle heater

R2/11 Washer nozzle hose heater

CAN B CAN class B

Washer nozzles and washer nozzle hose heaters, function

The washer nozzle heater (R2/1) and washer nozzle hose heater (R2/11) are switched on automatically when:

Circuit 61 ON (engine running) and

an outside temperature less than 5 °C is detected.

Switch off is accomplished automatically when:

Circuit 61 OFF (engine OFF) or

an outside temperature of more than 8 °C is detected.

In the event of no or implausible values (outside temperature, circuit 61) the heating elements are not actuated.

Actuation of heating elements

All heating elements for the washer nozzle heater (R2/1) and washer nozzle hose heater (R2/11) are connected in parallel.

The washer nozzle heater (R2/1) and washer nozzle hose heater (R2/11) are actuated directly by the front SAM control module with fuse and relay module (N10/1). During this process, the front SAM control module with fuse and relay module (N10/1) switches circuit 30 to the heating elements.

Required data

The outside temperature is measured by the outside temperature display temperature sensor (B14). The front SAM control module with fuse and relay module (N10/1) reads in the outside temperature display temperature sensor (B14) directly.

The status of circuit 61 (alternator (G2)) is also read in directly by the front SAM control module with fuse and relay module (N10/1).

Front SAM control module with fuse and relay module, location/task/design

GF54.21-P-4108Q

Outside temperature sensor, location/task/function

GF83.57-P-2119Q

Referenced documents