gf8050p2002pp

Activate anti-theft alarm system, function

Type gf · topic 80.50 · version 0108 · 2008-04-08

Applies to: MODEL 203.0 /2 /7 with CODE (551) Anti-theft alarm system (ATA [EDW]) up to Model Year 8

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.50 Anti-theft alarm system (ATA), Interior motion sensor/Tow sensor — Series 203 (models 0**, 2**, 7**)

GF80.50-P-2002PP

Activate anti-theft alarm system, function

8.3.06

MODEL 203.0 /2 /7
with CODE (551) Anti-theft alarm system (ATA [EDW])
up to Model Year 8

Function requirements:

Circuit 15C Off

Driver door closed

Activate anti-theft alarm system (ATA)

The anti-theft alarm system (ATA) is activated by locking the vehicle with the transmitter key (A8/1) or by using the relocking function.

The EIS control module (N73) relays the corresponding signal via the controller area network bus, class B (interior compartment) to the rear SAM control module with fuse and relay module (N10/2), which activates all alarm inputs of the anti-theft alarm system (ATA).

-----------------------------------------------------------------------------------------

Self- activation (only ):

If the driver door is opened or closed after removing the transmitter key (A8/1), the anti-theft alarm is activated automatically 2 minutes after the last door is closed, regardless of the locking status of the vehicle.

Feedback after successful activation

The LED in the TS/IMS switch with ATA function indicator (N72/1s7) (up to 23.4.04) or TS OFF switch and ATA function indicator (N72/1s27) (as of 24.4.04) comes on.

The alarm signal horn with additional battery (H3/1) is actuated momentarily three times (buzzing sound) (only as of 1.6.06 and ).

-----------------------------------------------------------------------------------------

Activate anti-theft alarm system (ATA) without tow-away protection (TS).

(as of 1.6.06 not with and )

Conditions of operation

Circuit 15 Off
(Status circuit 15C or circuit 15R not relevant)

anti-theft alarm system (ATA) not yet activated

Function

Momentarily actuate TS/IMS switch with ATA function indicator (N72/1s7) (up to 23.4.04) or TS OFF switch and ATA function indicator (N72/1s27) (as of 24.4.04). The integrated LED is illuminated as acknowledgment signal for 2 s (steady light).

Then activate anti-theft alarm system (ATA).

-----------------------------------------------------------------------------------------

Activate anti-theft alarm system (ATA) without interior protection (IMS)

(with code (882) Interior monitoring (with ATA only))

Function requirements:

Circuit 15 OFF
(Status circuit 15C or circuit 15R not relevant)

anti-theft alarm system (ATA) not yet activated

Function

Momentarily actuate TS/IMS switch with ATA function indicator (N72/1s7) (up to 23.4.04) or TS OFF switch (N72/1s19) (as of 24.4.04). The LED in the TS/IMS switch with ATA function indicator (N72/1s7) or TS OFF and ATA function indicator (N72/1s27) comes on for 2 s (turn signal lamp) as acknowledgment signal.

Then activate anti-theft alarm system (ATA).

-----------------------------------------------------------------------------------------

Notes on interior protection (IRS)

(with code (882) Interior monitoring (with ATA only))

The interior protection (IRS) is activated 30 s after the last door, trunk or rear door is closed. Then engine hood can be open

The status of the interior protection transmitter and receiver (A26/14) (model 203.0/2) and the left interior protection transmitter and receiver (A26/4) (model 203.7) is checked by the overhead control panel control module (N70). The alarm input is permitted only when the status check replies "OK".

Notes on tow-away protection (TS)

(as of 1.6.06 not with and )

The tow-away protection is activated approx. 10 s after the anti-theft alarm system (ATA) is activated.If one or more doors or the trunk lid are open, the ATA inclination sensor (B33) is activated after the last door, the trunk lid or the engine hood is closed.

Upper control panel control unit, location/task/design/function

GF54.21-P-4105PP

Rear SAM control unit with fuse and relay module, location/task/design/function

GF54.21-P-4115PP

Interior protection transmitter and receiver, location/task/design/function

Model 203.0/2 with code (882) Interior monitoring (with ATA only)

GF80.50-P-4104PP

Model 203.7 with code (882) Interior monitoring (with ATA only)

GF80.50-P-4104P

Inclination sensor, location/task/design/function

Up to 31.5.06,

As of 1.6.06 without code (494) USA version or without code (498) Japanese version

GF80.50-P-4105PP

Glass breakage sensor, location/task/design/function

Model 203.2 with code (882) Interior monitoring (with ATA only)

GF80.50-P-4107PS

Model 203.7 with code (882) Interior monitoring (with ATA only)

GF80.50-P-4107PC

Alarm signal horn, location/task/design/function

GF80.50-P-4110Q

Transmitter key, task/design/function

GF80.57-P-4101PP

Electronic ignition switch control unit, location/task/design/function

GF80.57-P-4102PP

Overhead control panel control unit, location/task/design

GF82.20-P-4110A

Referenced documents