GF80.45-P-2003PP | Convenience closing/opening with transmitter key function | 2.12.99 |
MODEL 203 up to Model Year 8
P72.29-2066-09
Convenience opening/closing via infrared signal
Networking of components shown on model 203.0
A8/1 Transmitter key
A26/1 Left front IR receiver unit
A26/2 Right front IR receiver unit
N69/1 Left front door control module
N69/2 Right front door control module
N69/3 Left rear door control module
N69/4 Right rear door control module
N70 Overhead control panel control module
N73 EIS [EZS] control module
M10/3 Left front power window motor
M10/4 Right front power window motor
M10/5 Left rear power window motor
M10/6 Right rear power window motor
M12m1 Roof system motor
Function requirements
Circuits 15C, 15R and 15 off
No overvoltage or undervoltage
All doors closed and
No other control module sending central opening/closing signals
Unlock/Lock button on transmitter key (A8/1) pressed for longer than 1 s.
Function
The corresponding control modules receive the CAN messages for convenience opening/closing and actuate the required motors. The motors remain actuated for as long as the button on the transmitter key is pressed, though for no longer than 25 s.
The convenience opening/closing function for the power windows operates even if windows are not normalized.
The convenience opening/closing function is aborted if
An obstruction is detected, or
The request is no longer received via the CAN, or
The function requirements listed above are no longer satisfied.
Referenced documents
- gf7229p3005pp Convenience closing of power windows, function
- gf7229p4102pp Rear door control module, location/purpose/design/function
- gf7229p4105pp Front driver-side door control module, location/purpose/design/function
- gf8045p0003pp Convenience feature (CF [KFB]) function