gf7720p3003t

Sliding/pop-up roof desynchronization, function

Type gf · topic 77.20 · version 0102 · 2003-06-02

Applies to: MODEL 211.0 /2 with CODE (414a) Electric glass sliding/pop-up roof

Where it sits

Function group 3 Body › 77 Sliding roof, soft top, top attachments › 77.20 Electric sliding roof — Series 211 (models 0**, 2**)

GF77.20-P-3003T

Sliding/pop-up roof desynchronization, function

11.12.01

MODEL 211.0 /2 with CODE (414a) Electric glass sliding/pop-up roof

Desynchronization occurs when:

the power supply has been interrupted.

the sliding/pop-up roof has exceeded the defined motion range by 25 rotations of the SR motor (M12m1).

one of the two Hall sensor signals is absent for t > 160 ms.

two Hall sensor signals are missing for t > 160 ms in spite of reversing of the sliding/pop-up roof.

the defined Hall sensor signal sequence is faulty.

a defect was recognized in the excessive force limiter.

In the desynchronized state, the position of the sliding/pop-up roof is not known.

The sliding/pop-up roof can only be moved manually in the "open sliding roof" and "open pop-up roof" direction with the roof system switch (N70s1).

Closing is no longer possible using the roof system switch (N70s1) because it cannot definitely identify the direction of motor rotation.

The drive is actuated for only approx. 0.2 s to indicate the desynchronized state and protect the mechanical end stop in the position "open sliding roof". It is then necessary to actuate the roof system switch (N70s1) again.

In order to restore the complete function, it is necessary to synchronize the sliding/pop-up roof.