gf7720p2016mx

Convenience opening of sliding/pop-up roof with recirculated air button, function

Type gf · topic 77.20 · version 0100 · 2002-10-11

Applies to: MODEL 240 with CODE (414A) Electric glass sliding/pop-up roof

Where it sits

Function group 3 Body › 77 Sliding roof, soft top, top attachments › 77.20 Electric sliding roof — Series 240

GF77.20-P-2016MX

Convenience opening of sliding/pop-up roof with recirculated air button, function

15.8.02

MODEL 240 with CODE (414A) Electric glass sliding/pop-up roof

Convenience opening of sliding/pop-up roof with recirculated air button,        
	function

P80.45-2031-09

1 Sliding/pop-up roof "open/closed"

2 Power window open/close

3 Cilrcuit 15

M10/3 Left front power window motor

M10/4 Right front power window motor

M10/5 Left rear power window motor

M10/6 Right rear power window motor

M12 Sliding/pop-up roof (SR [SHD]) drive unit

N22 AAC pushbutton control module

N69/1 Left front door control module

N69/2 Right front door control module

N69/3 Left rear door control module

N69/4 Right rear door control module

N70 Front overhead control panel control module

N73 EIS [EZS] control module

Function requirements:

Circuit 15R ON

Sliding/pop-up roof synchronized

No undervoltage/overvoltage

Automatic closing actuated via recirculated air switch

Headliner (only V240) completely open

Operation

Opening sliding/pop-up roof with recirculated air button

The sliding/pop-up roof opening function with recirculated air button is executed only when it was previously closed with the recirculated air function.

When the recirculated air button (N22s2) on the AC pushbutton control module (N22) is actuated the sliding/pop-up roof is actuated in the opening direction until the previously stored position is reached.

If closing via the recirculating air button is initiated again while opening, but before reaching the stored position, the opening position initially stored will be retained in memory.

The function is interrupted in the case of

intermediate manual actuation

detection of an obstruction

reaching the stored position

rescinding actuation request,

CAN message not present

When the sliding/pop-up roof is opened via recirculated air button the windows are also opened in the previously stored position.