gf7720p2000mx

Sliding/pop-up roof convenience opening, function

Type gf · topic 77.20 · version 0100 · 2002-10-11

Applies to: MODEL 240

Where it sits

Function group 3 Body › 77 Sliding roof, soft top, top attachments › 77.20 Electric sliding roof — Series 240

GF77.20-P-2000MX

Sliding/pop-up roof convenience opening, function

15.8.02

MODEL 240

Sliding/pop-up roof convenience opening, function

P80.45-2030-09

1 Direction of convenience opening

2 Sliding/pop-up roof "open/closed"

3 Power window "open/closed"

4 Sliding/pop-up roof pinch protection not active

5 Access authorization code

M12 Sliding/pop-up roof (SR [SHD]) drive unit

N69/1 Left front door control module

N69/2 Right front door control module

N69/3 Left rear door control module

N69/4 Right rear door control module

N70 Front overhead control panel control module

N73 EIS [EZS] control module

A8/1 Remote control key

A26/1 Left front IR receiver

A26/2 Right front IR receiver

M10/3 Left front power window motor

M10/4 Right front power window motor

M10/5 Left rear power window motor

M10/6 Right rear power window motor

Function requirements:

No overvoltage or undervoltage

C. 15C, 15R, 15 OFF

Hold "Unlock" button of remote control key (A8/1) pressed for longer than 1 s.

Operation

The overhead control panel control module (N70) receives the request for convenience opening over CAN and actuates the sliding/pop-up roof motor (M12m1). The motor is actuated in the "Open sliding roof" direction as long as the "Unlock" button on the remote control key (A8/1) is pressed

The convenience opening function for the sliding/pop-up roof is aborted if

the request is no longer received via CAN, or

the function prerequisites listed are no longer fulfilled.

In addition to opening the sliding/pop-up roof the convenience feature also opens the windows using the manual opening function

The convenience opening function is also possible with desynchronized sliding/pop-up roof.

Sliding/pop-up roof convenience closing, function

GF77.20-P-2001MX

Convenience opening of sliding/pop-up roof with recirculated air button, function

GF77.20-P-2016MX

Convenience closing of sliding/pop-up roof via recirculated air button, function

GF77.20-P-2017MX

Synchronizing sliding/pop-up roof, function

GF77.20-P-3002MX

Sliding/pop-up roof position measuring, function

GF77.20-P-3001MX

Sliding/pop-up roof lock-up recognition, function

GF77.20-P-3000MX

Remote control key, purpose/design/ function

GF80.57-P-4101MX

Referenced documents