GF40.16-G-2002A | Increasing tire inflation pressure function | 3.3.99 |
MODEL 437.111 /116 /120 /125 /136 /156 with CODE (A30) Tire control system
Select the relevant axle or all the axles with the selector switch. Then switch the "Inflate/deflate" switch to inflate. The 3/2-way valve (33.01a) and the 2/2-way valves (45.01a) are energized electrically.
The solenoids switch the directional valves to passage (inflate), the compressed-air can therefore flow out of the compressed-air reservoir (5.01) into the tires.
By inflating, the connection to the bypass valve with limited backflow is closed via the shuttle valves (28.03).
The tire pressures at the front and rear axle can be read off on the two pressure gauges (11.01, or 11.02 on 437.156) in the cab.
Referenced documents
- gf4016g5000a Overflow valve with limited backflow position/task
- gf4016g5002a Shuttle valve, location/task
- gf4016g5005a 2/2 directional control valve, location/task
- gf4016g5007a Tire pressure indicator, location/task
- gf4016g5009a Selector switch, location/task
- gf4016g5010a Compressed air reservoir, location/task
- gf4016g5011a Inflate/deflate switch, location/task
- gf4016g5013a 3/2 Inflate/deflate directional control valve, location/task