gf2000p0800c

Coolant circuit as-built configuration

Type gf · topic 20.00 · version 0102 · 1999-12-16

Applies to: ENGINE 112

Where it sits

Function group 1 Engine › 20 Engine cooling system › 20.00 General

EinPAS 15 Engine › 15.25 Engine cooling system › 15.25.1 Basic information

Also applies to engines/gearboxes: 112 ***

GF20.00-P-0800C

Coolant circuit as-built configuration

25.9.96

ENGINE 112

Coolant circuit as-built configuration

P20.00-0337-76

Diagram of coolant circuit model 210 with engine 112

1 2-stage coolant system cap

2 Coolant expansion reservoir with silicagel container

3 Radiator

4 Coolant thermostat (position when engine at operating temperature)

5 Coolant pump

6 Oil-water heat exchanger at oil filter

7 Vent pipe to coolant expansion reservoir

8 Heating system heat exchanger

A31 Heating system delivery unit

A31y2 Left duovalve

A31y2 Right duovalve

A Coolant return flow

B Coolant feed

C Bypass mode temperature < 87 °C

D Mixed mode temperature > 87 °C and < 102 °C thermostat opens, start of flow through radiator

E Cooling mode temperature > 102 °C thermostat open, full flow through radiator

M Engine

S Windshield washer fluid reservoir, coolant heated