gf1520p3003ib

Startglowing function

Type gf · topic 15.20 · version 0101 · 2003-05-05

Applies to: ENGINE 628.960 in MODEL 220.028 /128 ENGINE 628.961 in MODEL 211.028

Where it sits

Function group 1 Engine › 15 Electrical system - engine › 15.20 Preglow system — Series 211 (models 028) · Series 220 (models 028, 128) · Series 628 (models 960, 961)

GF15.20-P-3003IB

Startglowing function

14.9.99

ENGINE 628.960 in MODEL 220.028 /128

ENGINE 628.961 in MODEL 211.028

Startglowing function

P15.20-2031-76

0 Circuit15C

1 C. 15R ON

2 Circuit 15 ON

3 Circuit 50 ON

CAN Control Area Network

B11/4 Coolant temperature sensor

N3/9 CDI control unit

N14/2 Glow output stage

N73 DI control unit

R9 Glow plugs

During engine start (when transmitter key (A8/1) is turned into position 3 or in the case of KEYLESS GO automatically at the end of preglowing), start-up glowing is activated in order to stabilize the cold start speed.

The glow output stage (N14/2) is supplied with a signal by the CDI control unit (N3/9) to indicate that the engine is being started, the glow plugs (R9) continue to be supplied with voltage.

Afterglowing is activated when the starter release speed is reached.

If the transmitter key (A8/1) is not turned on into position 3 after the preglow indicator lamp has gone out, glow heating continues for a further 25 seconds or so, irrespective of the coolant temperature (start readiness glowing).

Electronic ignition switch control unit, location/task/design/function

Model 220

GF80.57-P-4102S

Electronic ignition switch control unit, location/purpose

Model 211

GF80.57-P-4120T

Glow output stage Location/Function/Design/function

GF15.20-P-2100IA

Glow plugs, location/task/design/function

GF15.20-P-3101I

Coolant temperature sensor location/task/design/function

GF07.04-P-5026I

CDI control unit, location/task

GF07.16-P-3101IB