GF07.51-P-3003D | HFM-SFI control module voltage supply function | 28.8.96 |
ENGINE 1 104.941 up to 31.7.96
except CODE (491) as of Model Year 97 USA version
except CODE (498) as of Model Year 97 Japanese version
ENGINE 104.942 /945 /992
ENGINE 104.943 /944 /991 /994 up to 31.7.96
ENGINE 104.995 except CODE (491) as of Model Year 97 USA version
except CODE (498) as of Model Year 97 Japanese version
ENGINE 111.921 /942 up to 31.8.98
ENGINE 111.945 up to 31.8.98 in MODEL 202.020 /080
ENGINE 111.945 up to 31.5.98 in MODEL 208.335
ENGINE 111.946 up to 31.5.98
ENGINE 111.960 /961 /970 /977
ENGINE 111.944 /975 up to 31.7.96
ENGINE 111.974 except CODE (491) as of Model Year 97 USA version
15.03.07 | The document has been updated to this date and will no longer be subject to revision. |
P07.51-2037-06
F1 Fuse and relay module circuit 15, model 163
K1/2 Overvoltage protection relay, model 124, 202 up to 7/96
K40 Relay module, model 170, 210
K40/4 Fuse and relay module,
model 202 as of 8/96, 208
N3/4 HFM-SFI control module
N16/1 Base module, model 129, 140
W Ground
(several ground cables e.g. for ignition output stages or electronics depending on version and also LHS and RHS)
Voltage supply
The HFM-SFI control module is supplied with voltage (fused/ unfused) at circuit 87 and 30 as follows.
To relieve the plug connections, voltage is supplied in some cases through several pins connected in parallel with bridges.
-----------------------------------------------------------------------------------------
GND connections output stages
Several GND connections of the ignition output stages and the GND of the electronics are bolted on close to the HFM-SFI control module.
-----------------------------------------------------------------------------------------
Referenced documents
- gf5410p4033k Relay module position/task/design/function
- gf5410p4100a Overvoltage protection relay, location/task/design/function
- gf5421p4013l Base module Location/Function/Design/Operation