P91.60-3092-09
1 | Instrument panel | 3 | Wiring harness | |
4 | Nuts | |||
2 | Front passenger airbag |
P91.60-3093-07
1 | Instrument panel | R12/4 | Front passenger airbag squib 1 | |
2 | Front passenger airbag | R12/5 | Passenger airbag squib 2 | |
4 | Nuts |
Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Notes on self-locking nuts and bolts | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m) | ||
2 | Disconnect battery ground line | ||
3 | Dashboard (1) removal | ||
4 | Unscrew nuts (4) and remove front passenger airbag (2) from instrument panel (1) | | |
If the front passenger airbag (2) is replaced, the wiring harness (3) must be replaced. | |||
Installation: The wiring harness (3) for the front passenger airbag unit (2) must be correctly routed. It must not be jammed or pass between the front passenger airbag unit (2) and the dashboard (1)! | |||
Nut, front passenger airbag unit to dashboard | |||
5 | Install in the reverse order | ||
| Check | ||
6 | Connect diagnostic system; read out fault memory | When replacing front passenger airbag (2). | |
|
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ah0000n000101a Notes on self-locking nuts and bolts
- ah5400p000101a Information on preventing damage to electronic components due to electrostatic discharge
- ah9100z000010a Information, assessment and legal requirements when working with, handling and storing pyrotechnical components
- ar5410p0003rt Disconnect/connect battery ground line
- ar6810p1000rt Remove/install dashboard
- as9100z000801a Risk of injury during testing and repair operations related to pyrotechnical components