1 | Gas shut-off cocks |
D86.60-0211-05
2 | Hose |
3 | Hose clamps |
4 | Hoses |
5 | Electrical connector |
6 | Drawer |
7 | Connection piece |
8 | Caps |
11 | Hose clamp |
D86.60-0213-06
9 | Bolts |
10 | Stove/sink unit |
D86.60-0013-11
Danger ! | Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas. | Remove any sources of ignition. | |
| Notes on carrying out repair work in the vehicle interior | ||
| Remove/install | ||
1 | Close gas shutoff cocks (1) | See Owner's Manual. | |
2 | Unfasten hose clamp (11) | ||
3 | Detach hose (2) | ||
4 | Loosen hose clamps (3) | ||
5 | Mark position of hoses (4) | ||
6 | Detach hoses (4) | ||
7 | Check hose clamps (3, 11) and hoses (2, 4) for damage, replace if necessary | ||
8 | Disconnect electrical connection (5) | ||
9 | Remove drawer (6) | ||
10 | Disconnect connection piece (7) | ||
11 | Remove caps (8) | ||
12 | Loosen screw/bolts (9) | ||
13 | Remove stove/sink unit (10) | ||
14 | Install in the reverse order | ||
15 | Check gas system for leakage | It is necessary that the leaktightness and function test is performed and documented by an authorized specialist after opening the gas system. | |
16 | Check fresh water system for leakage | ||
17 | Check sealant in waste water tank |
Referenced documents
- ah6800n000101s Notes on carrying out repair work in the vehicle interior
- ar8660d0020ec Remove/install drawer
- as0000z001801a Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves