ar8660d0010ec

Remove/install hot water heater/sink combination

Type ar · topic 86.60 · version 0101 · 2016-06-11

Applies to: Model 903.6 with code ZL9 (James Cook touring camper)

Where it sits

Function group 3 Body › 86 Emergency equipment, diability equipment, sanitary equipment, galley › 86.60 Galley — Series 903 (models 6**)

EinPAS 37 Interior equipment › 37.76 Kitchenette/cool box › 37.76.30 Kitchen appliances — Series 903 (models 6**)

AR86.60-D-0010EC

Remove/install hot water heater/sink combination

30.05.2016

Model

903.6

with code ZL9 (James Cook touring camper)

Remove/install hot water heater/sink combination

1

Gas shut-off cocks

D86.60-0211-05

Remove/install hot water heater/sink combination

2

Hose

3

Hose clamps

4

Hoses

5

Electrical connector

6

Drawer

7

Connection piece

8

Caps

11

Hose clamp

D86.60-0213-06

Remove/install hot water heater/sink combination

9

Bolts

10

Stove/sink unit

D86.60-0013-11

Danger !

Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas.

Remove any sources of ignition.
Protective clothing, safety gloves and safety glasses must always be worn.
Ensure that the work area is adequately ventilated.
When working on vehicles at ambient temperatures over 60 °C, all gas cylinders must be removed.

AS00.00-Z-0018-01A

Notes on carrying out repair work in the vehicle interior

AH68.00-N-0001-01S

Remove/install

1

Close gas shutoff cocks (1)

See Owner's Manual.

2

Unfasten hose clamp (11)

3

Detach hose (2)

4

Loosen hose clamps (3)

5

Mark position of hoses (4)

6

Detach hoses (4)

7

Check hose clamps (3, 11) and hoses (2, 4) for damage, replace if necessary

8

Disconnect electrical connection (5)

9

Remove drawer (6)

AR86.60-D-0020EC

10

Disconnect connection piece (7)

11

Remove caps (8)

12

Loosen screw/bolts (9)

13

Remove stove/sink unit (10)

14

Install in the reverse order

15

Check gas system for leakage

It is necessary that the leaktightness and function test is performed and documented by an authorized specialist after opening the gas system.

16

Check fresh water system for leakage

17

Check sealant in waste water tank

Referenced documents