ar8370p5652f

Remove/install fuel metering pump

Type ar · topic 83.70 · version 0103 · 2004-10-21

Applies to: MODELS 168.006 1#, 168.007 /008 1# as of 1.3.01, 168.009 /031 /032 /033 /109 1#, 168.131 /132 /133 1# as of 1.3.01 Retrofitted Thermo Top C stationary heater

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 168 (models 006, 007, 008, 009, 031, 032, 033, 109, 131, 132, 133)

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.46 Pump/container — Series 168 (models 006, 007, 008, 009, 031, 032, 033, 109, 131, 132, 133)

AR83.70-P-5652F

Remove/install fuel metering pump

28.4.98

MODELS 168.006 1#,
168.007 /008 1# as of 1.3.01,
168.009 /031 /032 /033 /109 1#,
168.131 /132 /133 1# as of 1.3.01
Retrofitted Thermo Top C stationary heater

Remove/install fuel metering pump

P83.70-2065-06

1 Fuel intake line

2 Fuel pressure line

3 Coupling, voltage supply

4 Rubber mounts

Y23 Fuel metering pump

Remove/install

1

Remove center underfloor paneling

AR61.20-P-1105GC

2

Detach fuel lines (1)

*000589403700

Danger!

Risk of explosion from fuel igniting, risk of poisoning from inhaling and swallowing fuel as well as risk of injury to eyes and skin from contact with fuel.

No fire, sparks, naked flames or smoking.
Pour fuels only into suitable and appropriately marked containers.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

3

Detach fuel lines (1, 2) from the fuel metering pump (Y23)

Collect fuel drips.

4

Unclip coupling (3) for electric connection line

5

Detach fuel metering pump from the rubber mounts (4)

6

Install in the reverse order

Checking

Danger!

Risk of explosion due to fuel vapors, risk of poisoning from breathing in combustion gases and risk of injury due to combustions during or after heating operation

Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves.

AS83.70-Z-0002-01A

7

Start up stationary heater

Start up stationary heater

If the heater (A6) switches off automatically before reaching its operating temperature and if it cannot be restarted, there is a fault interlock:

AZ83.70-P-0008-04A

Cancel fault interlock

AR83.70-P-5302-07A

Remove/install fuel metering pump

000 589 40 37 00

Clamp

Referenced documents