ar8350d6030a

Remove/install the air conditioning's (roof equipment) relay

Type ar · topic 83.50 · version 0102 · 2019-11-28

Applies to: Model 903.662 with code Z29 (James Cook touring camper, NAFTA) with code ZU8 (National version for USA) Roof-mounted air conditioning system load relay at power supply unit

Where it sits

Function group 3 Body › 83 Climate control › 83.50 Rear air-conditioning — Series 903 (models 662)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.11 Control unit/relay — Series 903 (models 662)

AR83.50-D-6030A

Remove/install the air conditioning's (roof equipment) relay

18.11.2019

Model

903.662

with code Z29 (James Cook touring camper, NAFTA)

with code ZU8 (National version for USA)

Roof-mounted air conditioning system load relay at power supply unit

Remove/install the air conditioning's (roof equipment) relay

D83.50-1160-09

1

Power supply unit cover

4

Electrical line

7

Electrical line

2

Load relay

5

Electrical line

8

Nuts

3

Electrical line

6

Electrical line

Remove/install

Danger

Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)

Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines.

AS00.00-Z-0035-01A

1

Switch off roof-mounted air conditioning system

See owner's manual.

2

Disconnect external 110 V feed line from vehicle

See owner's manual.

3

Remove web-type fuse

Roof-mounted air conditioning system in the engine compartment

AR54.15-D-2100B

4

Remove power supply unit cover (1)

AR54.21-D-0030-01A

5

Mark installation position of electric lines (3, 4, 5, 6, 7) at load relay (2)


Swapping the electric lines (3, 4, 5, 6, 7)
may lead to short circuit and therefore destruction of electrical component parts.

6

Unscrew nut on electric line (3)

7

Remove electric line (3) from load relay (2)

8

Unscrew screw on electric line (4)

9

Remove electric line (4) from load relay (2)

10

Unscrew screw on electric line (5)

11

Remove electric line (5) from load relay (2)

12

Unscrew nut on electric line (6)

13

Remove electric line (6) from load relay (2)

14

Unscrew nut on electric line (7)

15

Remove electric line (7) from load relay (2)

16

Unscrew nuts (8)

Installation: Replace self-locking nuts (8).

17

Remove load relay (2)

18

Install in the reverse order

19

Perform function test

Switch roof-mounted air conditioning system on/off (see operator's manual).

Referenced documents