ar8350d5040a

Remove/install the air conditioning's evaporator unit (roof equipment)

Type ar · topic 83.50 · version 0205 · 2020-02-03

Applies to: Model 903.66/67, 904.66 with code H08 (Roof-mounted air conditioning system, reinforced) -

Where it sits

Function group 3 Body › 83 Climate control › 83.50 Rear air-conditioning — Series 903 (models 66*, 67*) · Series 904 (models 66*)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.32 Housing/heat exchanger/evaporator/filter — Series 903 (models 66*, 67*) · Series 904 (models 66*)

AR83.50-D-5040A

Remove/install the air conditioning's evaporator unit (roof equipment)

20.01.2020

Model

903.66/67, 904.66

with code H08 (Roof-mounted air conditioning system, reinforced)

-

Modification notes

08.10.2004

Mounting bolt, evaporator unit to roof changed from 28 Nm to 25 Nm

Value on model 903.6, 904.6 with code H08 changed

BA83.50-N-1004-01B

Remove/install the air conditioning's evaporator unit (roof equipment)

4

Grommet

X299

Roof air conditioning fan connector

X310b1

High pressure switch

D83.50-1220-01

Remove/install the air conditioning's evaporator unit (roof equipment)

D83.50-1136-09

1

Evaporator unit

5

Rubber-absorber disk

9

Bitumen insulation tape

2

Terminal stud, terminal 30

6

Condensation hose

10

Union nut

3

Ground line, terminal 31

7

Sheet metal screw

11

Union nut

4

Grommet

8

Interior lights wiring harness

X220

Roof air conditioning connector

Remove/install

Danger

Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area.

Model 903.66 (except 903.662), 903.67, 904.66
with code H08 (Roof-mounted air conditioning system, reinforced)-

AS65.00-Z-0002-01A

Danger

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

Model 903.66 (except 903.662), 903.67, 904.66
with code H08 (Roof-mounted air conditioning system, reinforced)-

AH83.30-N-0005-01A

Topical note

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

1

Disconnect battery ground line

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

2

Remove evaporator unit trim (1)

AR83.50-D-5010A

3

Drain air conditioning system

AR83.30-D-1760B

4

Remove paneling of condenser unit

AR83.50-D-5000A

5

Push grommet (4) inwards

Installation: Seal grommet (4) with sealant.

Terostat 8590

*BR00.45-Z-1041-02A

6

Disconnect condenser fan connector (X299) and high-pressure switch connector (X310b1), and pull lines into interior compartment

7

Disconnect roof air conditioning connector (X220)

8

Detach wiring harness for interior lights (8) from evaporator unit (1)

9

Unscrew line from terminal stud for terminal 30 (2)

Model 903.66 (except 903.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.66 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
-Nut, terminal 30 terminal stud

*BA83.50-N-1021-01B

10

Remove bitumen insulation tape (9) over refrigerant lines

Installation: Wrap area around expansion valve, low-pressure switch and the evaporator pipe lines carefully with new bitumen insulation tape (9).

Insulation

*BR00.45-Z-1062-01A

11

Unscrew union nut (10)

Compressor oils (specification 362.0)

BB00.40-P-0362-00A

Plug openings.

Installation: Use new sealing ring. Coat sealing ring with compressor oil before installation.

Model 903.66 (except 903.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.66 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
*Nut, refrigerant line connection to expansion valve

*BA83.50-N-1002-01B

Record plug

*129589009100

12

Unscrew union nut (11)

Compressor oils (specification 362.0)

BB00.40-P-0362-00A

Plug openings.

Installation: Use new sealing ring. Coat sealing ring with compressor oil before installation.

Model 903.66 (except 903.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.66 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
*Line connection, intake-side refrigerant lines

*BA83.50-N-1017-01B

Record plug

*129589009100

13

Disconnect condensation hoses (6) on left and right side of evaporator unit (1)

14

Remove self-tapping screws (7)

15

Support, unscrew and remove evaporator unit (1)

Installation: Screw on ground line for terminal 31 (3).
Use new rubber absorber disks (5).

Model 903.66 (except 903.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.66 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)
*Mounting bolt, evaporator unit to roof

*BA83.50-N-1004-01B

16

Install in the reverse order

Only attach trim of evaporator unit and condenser unit after filling and checking the air conditioning system.

17

Replace air conditioning system filter dryer

AR83.50-D-5090A

18

Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak

AR83.30-D-1760B

19

Set time on instrument cluster

except code J19 (Automatic 1 day/2 driver tachograph (EU)) except code J28 (Tachograph 1 day/2 driver with additional recorder. 2-stage)

20

Set time on timer for auxiliary heater

with code H12 (Hot-water auxiliary heater) or with code H86 (Analog clock for auxiliary heater)

21

CODE RADIO

Rear air conditioning

Number

Designation

Model 903.6 (except 903.663/671/672/673)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.6 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)

BA83.50-N-1002-01B

Nut, refrigerant line connection to expansion valve

Nm

35

Rear air conditioning

Number

Designation

Model 903.6 (except 903.663/671/672/673)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.6 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)

BA83.50-N-1004-01B

Mounting bolt, evaporator unit to roof

Nm

25

Rear air conditioning

Number

Designation

Model 903.6 (except 903.663/671/672/673)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.6 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)

BA83.50-N-1017-01B

Line connection, intake-side refrigerant lines

Nm

35

Rear air conditioning

Number

Designation

Model 903.6 (except 903.663/671/672/673)
with code H08 (Roof-mounted air conditioning system, reinforced)
except code HH6 (Air conditioning, roof equipment)
except code HH7 (Roof-mounted air conditioning system, basic)
except code HK2 (Air conditioning in rear with underfloor condenser)
Model 904.6 (except 904.663)
with code H08 (Roof-mounted air conditioning system, reinforced)

BA83.50-N-1021-01B

Nut, terminal 30 terminal stud

Nm

20

Remove/install the air conditioning's evaporator unit (roof equipment)

129 589 00 91 00

Record plug

Repair materials

Number

Designation

Order number

BR00.45-Z-1041-02A

Terostat 8590

Henkel Teroson GmbH
Hans-Burte-Strasse 4
69123 Heidelberg
Germany
Tel. +49 6221704-0
Fax +49 6221704-698
www.teroson.de

BR00.45-Z-1062-01A

Insulation

A 901 831 13 96

Referenced documents