AR83.30-P-7813RR | Remove/install refrigerant line between condenser and refrigerant compressor | 21.11.06 |
MODEL 452.3 /4
with CODE (I01) Air conditioning Plus
with CODE (I29) Air conditioning Plus (with combination filter and outside temperature indicator), smart & passion
P83.30-4346-09
1 Nut
3 Intake line quick-release coupling
2 Intake lines
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Removing | ||
1 | Remove luggage compartment pan | ||
2 | Discharge air conditioning system | ||
3 | Remove underfloor paneling | ||
4 | Remove rubber retainer from line clip of refrigerant lines | ||
5 | Unscrew nut (1) from intake and pressure lines at condenser | | |
6 | Detach intake lines (2) and remove sealing ring | Seal off refrigerant lines so that they cannot be penetrated by soiling and damp. | |
7 | Undo intake line (3) quick-release coupling | Cutting tool set | |
8 | Remove intake lines (2) | ||
| Install | ||
9 | Position intake lines (2) | ||
10 | Attach intake line (3) to quick-release coupling | Cutting tool set | |
11 | Fit intake line sealing ring | ||
12 | Unscrew nuts (1) of intake and pressure lines at condenser | | |
13 | Fasten retaining rubber band on line clip of refrigerant lines | ||
14 | Install underbody paneling | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
15 | Replace filter drier | Replace the fluid reservoir every time you open up the refrigeration circuit. When a receiver/dryer is left open, the dryer unit quickly becomes saturated with moisture, rendering it useless. | |
16 | Fill air conditioning system | ||
17 | Install luggage compartment tray | ||
18 | Perform air conditioning system function test | ||
19 | Read out fault memory | If necessary, eliminate faults in the control units. | |
| Connect STAR DIAGNOSIS and read out fault memory | STAR DIAGNOSIS diagnosis system |
Air conditioning system
Cutting tool set
452 589 00 33 00
Referenced documents
- ad0000p200004rr Connect STAR DIAGNOSIS and read out fault memory
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ar6130p1001rr Remove/install underfloor paneling
- ar8330p1760rr Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks
- ar8330p6525rr Remove/install dehydrator
- as8300z000101a Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.