P83.30-4454-09
Shown on model 164.077 |
1 | Bolts | 5 | Screw | |
2 | Bracket | 6 | Bolts | |
3 | Oil cooler | 7 | Fluid reservoir | |
4 | Guide pins |
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
1 | Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks |
| |
Model 251.077/177 | |||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
2 | Remove front bumper |
| |
Model 251.077/177 | |||
3 | Unscrew the nuts (1) | Nut connecting bracket to retaining frame | |
4 | Remove holder (2) | ||
5 | Pull oil cooler (3) to side (arrow) | Installation: Ensure correct installation position of guide pins (4) in bracket (2). | |
6 | Remove bolt (5) | Nut/bolt, high-pressure line to fluid reservoir | |
Record plug | |||
7 | Remove bolts (6) | Bolt, fluid reservoir to condenser | |
8 | Remove fluid reservoir (7) | Installation: | |
Installation: Use new fluid reservoir (7). | |||
Installation: Replace sealing ring of refrigerant line and moisten with compressor oil. | |||
9 | Use suitable plug to seal opening of refrigerant line and suitable stop plug to seal opening of fluid reservoir (7) | | |
Record plug | |||
10 | Install in the reverse order |
129 589 00 91 00
Record plug
Referenced documents
- ah8330n000301a Notes on handling refrigerant R134a
- ah8330n000401a Procedure for a damaged or leaky air conditioning system
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ar8330p1760gz Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks
- ar8330p1760rt Drain, evacuate and refill air conditioning, check function and check for leaks
- ar8820p2000gz Remove/install front bumper
- ar8820p2000rt Remove/install front bumper
- as8300z000101a Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.
- ws8300p0031b 000 588 04 82 00 Air conditioning service unit R134a
- ws8300p0034b 000 588 10 82 00 R1234yf air conditioning service unit