1 | Condenser |
2 | Union nut |
3 | Connector |
M83.50-0016-11
| Remove/install | ||
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
1 | Drain air conditioning system | ||
2 | Disconnect connector coupling (3) | ||
3 | Unscrew union nuts (2) | ||
| |||
Plug openings. | |||
Installation: Install new sealing rings. Coat sealing rings with compressor oil before installation. | |||
Torque tool kit | |||
Connector for refrigerant lines | |||
Record plug | |||
4 | Remove condenser (1) | Installation: Determine remaining quantity of compressor oil | |
Mounting bolt, underfloor condenser to bracket | |||
Total compressor oil filling capacity of air conditioning system (including AC compressor) | |||
5 | Install in the reverse order | ||
6 | Replace air conditioning system filter drier | ||
7 | Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak |
Air conditioning |
Number | Designation | Model 903.663, 904.663 with air conditioning system SC1-9 | Model 903.663, 904.663 with air conditioning system SC4-10 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 150 | 340 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 904.663 with air conditioning system SC3-11 with additional condenser | Model 904.663 with roof air conditioning system Sütrak AC 111 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 220 | 500 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 904.663 with air conditioning systemSC2-10 | Model 904.663 with air conditioning systemSC3-10 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 180 | 220 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 904.663 with air conditioning systemSC5-10 | MODEL 905.613 with Hispacold roof air conditioningD5 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 500 | 460 | |
Specifications for Operating Fluids, Sheet | |||||
Air conditioning |
Number | Designation | Model 905.613 with air conditioning system SC3-11 with additional condenser | Model 905.613 with roof air conditioning system Sütrak AC 111 | ||
BF83.30-N-1002-01G | Total compressor oil filling capacity of air conditioning system (including AC compressor) | cm3 | 250 | 550 | |
Specifications for Operating Fluids, Sheet | |||||
129 589 00 91 00
Record plug
Referenced documents
- ah8330n000301a Notes on handling refrigerant R134a
- ah8330n000401a Procedure for a damaged or leaky air conditioning system
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ar8330m1760a Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks
- ar8330m1760a
- ar8330m6525a
- ar8330m6525a Remove/install dehydrator
- as0000z001701a Risk of injury caused by scraping or cutting body parts on sharp vehicle parts
- as8300z000101a Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.
- bb0040p036200a Compressor oils (specification 362.0)