D83.30-1303-78
1 | Evaporator | 2 | Air distribution housing | |
1.1 | AC housing | 3 | Drain hose |
4 | Expansion valve |
4.1 | Clamping claw |
D83.30-1306-81
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Remove/install | ||
1 | Remove air conditioner housing (1.1). | ||
The evaporator (1) and the air conditioner housing (1.1) are a single component part and they cannot be individually replaced. | |||
2 | Remove air distribution housing (2). | When replacing evaporator (1) or the air conditioner housing (1.1). | |
3 | Remove blower motor. | When replacing evaporator (1) or the air conditioner housing (1.1). | |
4 | Remove fresh/recirculated air housing. | When replacing evaporator (1) or the air conditioner housing (1.1). | |
5 | Remove expansion valve (4). | When replacing evaporator (1) or the air conditioner housing (1.1). | |
Model 907, 910 | |||
6 | Remove clamping claw (4.1). | When replacing evaporator (1) or the air conditioner housing (1.1). | |
7 | Remove drain hose (3). | When replacing evaporator (1) or the air conditioner housing (1.1). | |
8 | Install in the reverse order. |
Referenced documents
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ar8310d0006ts Remove/install housing for air distribution
- ar8310d0007ts Remove/install housing for fresh/recirculated air
- ar8325d1200ts Removing and installing blower motor
- ar8330d5200ts Remove/install air conditioner housing
- ar8330d5520tsr Remove/install expansion valve