ar8325a1000b

Remove/install heater housing

Type ar · topic 83.25 · version 0102 · 2004-02-03

Applies to: MODELS 690.6 with code (HH9) Automatic air conditioning "Tempmatic"

Where it sits

Function group 3 Body › 83 Climate control › 83.25 Automatic heater — Series 690 (models 6**)

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.32 Housing/heat exchanger/evaporator/filter — Series 690 (models 6**)

AR83.25-A-1000B

Remove/install heater housing

6.6.01

MODELS 690.6 with code (HH9) Automatic air conditioning "Tempmatic"

Remove/install heater housing

D83.25-1104-06

1 Heater housing

2 Electrical connector

3 Electrical wire

4 Electrical connector

5 Screw

6 Electrical connector

7 Condensed water hose

Modification notes

17.10.03

Repair method optimized.

Step 3

Remove/Install

Danger!

Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning. Inhaling overheated refrigerant vapors may be toxic. Risk of injury. Contact with liquid refrigerant may result in injury to the skin and eyes.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged.

AS83.00-Z-0001-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

1

Discharge air conditioning system

AR83.30-D-1760A

2

Remove instrument panel

Installation: If control cables for air distribution have been removed:

AR68.10-A-1000A

Adjust air distribution control cables

AR83.10-D-1400-01A

3

Detach ventilation box and put down on engine

Do not disconnect electrical connector from ventilation box.

AR83.10-D-0010-03A

4

Position suitable catch reservoir for coolant below vehicle

5

Remove connections from heater at front

AR83.25-D-1000-01A

*BA83.30-N-1008-02A

*000589672100

6

Remove air ducts

AR83.25-D-1000-02A

7

Disconnect electrical connector (2) on outlet air temperature sensor

8

Expose electrical line (3) and disconnect electrical connector (4)

9

Unscrew bolts (5).

10

Disconnect electrical connector (6) at evaporator temperature sensor

11

Remove condensate water hose (7)

12

Remove heater housing (1)

Installation: Ensure that electrical line (3) to ventilation box is routed properly. Check seals for the air outlet and inlet openings, replace if necessary.

13

Install in the reverse order

14.1

Set time at instrument cluster

Except with tachograph Latin America code J05.

15

Evacuate the air conditioning system, re-fill it, and then check the system to make sure that it functions correctly and does not leak.

AR83.30-D-1760A

16

Read diagnostic trouble code memory and erase

Stored faults which may be caused by disconnecting lines or by simulation during removal and installation or inspection work, must be processed and erased in the fault memories after completing the work.

Refrigerant lines

Number

Designation

Models
690.6, 903.6 with code HH6, HH9

BA83.30-N-1008-02A

Screw for refrigerant line connector block on evaporator

Nm

5 (0.5)

Remove/install heater housing

Torque wrench

000 589 67 21 00

Referenced documents