P83.10-2549-07
1 Instrument panel
2 Electrical connector
3 Bolts
4 Bolts
5 Actuator motor housing
M16/24 Right center air flap actuator motor
| Remove/install | ||
1 | Instrument panel (1) removal | Put down instrument panel (1) on a suitable base to avoid damage. | |
2 | Remove bolts (4) and remove actuator motor housing (5) from instrument panel (1) | ||
3 | Detach electrical connector (2) from right center air flap actuator motor (M16/24) | ||
4 | Remove bolts (3) | ||
5 | Detach right center vent air flap actuator motor (M16/24) | ||
6 | Install in the reverse order | ||
7 | Normalize right center air outlet flap actuator motor (M16/24), read out and delete fault memory | STAR DIAGNOSIS diagnosis system | |
| Connect STAR DIAGNOSIS and read out fault memory |
Commercially available tools
Referenced documents
- ad0000p200004a Connect STAR DIAGNOSIS and read out fault memory
- ad0000p200004a
- ar6810p1000rt Remove/install dashboard